Installing the isolator lead
1.
Remove the cap
a
.
2.
Connect the isolator lead coupler
b
.
TIP:
Pass the isolator lead
a
over the battery
cables
b
so that they do not cross over each
other.
Installing the water pressure sensor
See 6Y8 Multifunction Meter set up manual
for details of the components.
1.
Remove the braided plug
a
and gasket
b
.
2.
Install a new gasket
c
and the adapter
d
, and then tighten the adapter
d
to the
specified torque.
NOTICE:
Do not
reuse a gasket, always replace it with
a new one.
3.
Install the water pressure sensor
e
, and
then tighten it to the specified torque.
4.
Remove the water pressure sensor
harness
a
from the holder
f
.
5.
Remove the water pressure sensor
coupler
b
from the bracket
g
, and then
remove the cap
c
.
b
c
a
b
b
b
a
Water pressure sensor adapter
d
:
23 N·m (2.3 kgf·m, 17.0 ft·lb)
Water pressure sensor
e
:
18 N·m (1.8 kgf·m, 13.3 ft·lb)
b
a
c
d
e
Summary of Contents for F225F
Page 1: ...SERVICE MANUAL 6CE 28197 3N 11 F L 225F F L 250D F L 300B ...
Page 4: ......
Page 54: ...1 31 SPEC Specification MEMO ...
Page 89: ...2 34 Lower unit 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 263: ...6 28 Canister 0 1 2 3 4 5 6 7 8 9 10 A j k f b ...
Page 477: ...8 98 Shimming counter rotation model 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 537: ...9 58 PTT cylinder 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 562: ...A 1 MEMO ...
Page 565: ......
Page 566: ...May 2010 1 ABE E_1 YAMAHA MOTOR CO LTD ...
Page 576: ...A 13 ...