5-42
Charging unit and component
0
1
2
3
4
5
6
7
8
9
10
A
Checking the Rectifier Regulator
Do not connect the battery cables in
reverse. Otherwise, the Rectifier Regula-
tor could be damaged.
1.
Remove the fuse cover
a
.
2.
Measure the Rectifier Regulator output
peak voltage.
TIP:
Do not use peak voltage adapter B when
measuring the Rectifier Regulator output
peak voltage.
3.
Remove the intake manifold (STBD).
4.
Disconnect the Rectifier Regulator
couplers
a
,
b
,
c
,
d
, and
e
and
ground lead
f
.
5.
Remove the fuse holder, and then
remove the Rectifier Regulator couplers
g
,
h
, and
k
.
6.
Set the digital circuit tester to the diode
mode, and then check the Rectifier
Regulator for continuity.
Rectifier Regulator output peak voltage:
Fuse (100 A)–Ground
r/min
Loaded
1500
3500
DC V
13.0
13.0
a
a
b
c
d
e
f
h
g
k
B
m
n
p
r
s
v
t
u
w
x
y
A
Summary of Contents for F225F
Page 1: ...SERVICE MANUAL 6CE 28197 3N 11 F L 225F F L 250D F L 300B ...
Page 4: ......
Page 54: ...1 31 SPEC Specification MEMO ...
Page 89: ...2 34 Lower unit 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 263: ...6 28 Canister 0 1 2 3 4 5 6 7 8 9 10 A j k f b ...
Page 477: ...8 98 Shimming counter rotation model 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 537: ...9 58 PTT cylinder 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 562: ...A 1 MEMO ...
Page 565: ......
Page 566: ...May 2010 1 ABE E_1 YAMAHA MOTOR CO LTD ...
Page 576: ...A 13 ...