SELECTED INPUT CHANNEL block
21
+48/ø/INSERT (+48/phase/insert) section
In this section you can switch phantom power on/off, reverse the phase, and switch insertion on/off.
1
[+48 V] switch and LED
If an AD card with head amp is patched to the chan-
nel, this switch turns the phantom power on/off.
(The switch LED will light when if phantom power is
on.)
For a channel to which another card is patched, this
switch has no function.
The +48V switch on the front panel of the AI8
input unit is the master phantom switch for the
entire unit.
Be aware that if the master phantom switch is off,
that unit cannot use phantom power.
2
[ø] (Phase) switch and LED
This switches the input signal between normal and
reverse phase. The LED will light if the phase has
been inverted.
3
[INSERT] switch and LED
This switch turns channel insertion on/off.
When insertion is on, the switch LED will light, and
the insert out/in points specified in the display (IN
PATCH function INSERT PATCH screen) will be
enabled.
Be aware that if you turn on the [INSERT] switch
when the insert out/in points are not patched to
appropriate jacks, a signal may not be input to that
channel.
INSERT
+48V
+48V / / INSERT
1
2
3