Manual Ozone Generating System
SMOevo
PLUS
Transport and Storage
Manual_SMOevoPLUS_eng_01.2019.doc
page 68 of 179
6.4 Packaging
6.4.1 Packaging on Delivery
The complete ozone generating system is sealed in foil in order to protect it from soil and
rain. Desiccant additive protects the system from moisture.
After receipt of the ozone system, observe the following instructions:
•
Unpack the ozone system according to the sequence of installation.
•
Remove all packing material (desiccant) and dispose it of properly and in an
environmentally sound manner observing locally applicable regulations.
•
Remove any condensate which may have developed during transport.
•
Prior to putting the system into operation, store it at least 24 hours in order to avoid
malfunctions due to condensation.
6.4.2 Packaging during Transport and Storage
When packing the system for storage or transport purposes, observe the following
instructions:
•
In order to prevent damage, pack and unpack the different System Components
according to their function and depending on their sensitivity with regard to damage.
•
Protect the system from moisture.
•
Protect the system from damage due to contact with other objects.
•
Protect the system from frost if various parts of the system contain water.
•
Protect the system from excessive air humidity (risk of corrosion due to
condensation!).
•
Seal the system in plastic foil and add desiccant as moisture protection.
6.5 Storage
Observe the following instructions in order to ensure safe storage:
•
Store the ozone system in dry rooms only.
•
Store the ozone system in such way that risk of damage is excluded.
•
Store the complete system including all individual parts to make sure that all parts are
available when the system is commissioned again.
•
Completely remove the coolant from the ozone generators if the storage temperature
is / is expected to be below 0°C.
•
Protect the parts from corrosion.
•
Ensure airtight closure of the gas inlets and outlets.