Manual Ozone Generating System
SMOevo
PLUS
Maintenance
Manual_SMOevoPLUS_eng_01.2019.doc
page 168 of 179
P&ID
No.
Component
What to do
Interval
03.1.15
Motor control
valve with
actuator
Visual inspection
monthly
03.1.20
Check valve
Visual inspection
every 6 months
03.1.01
Solenoid valve
Visual inspection
every 6 months
Piping
Visual inspection
weekly
Assembly: Cooling system
07.1.15
Flow meter
Visual inspection
every 6 months
07.1.25
Temperature
sensor
Visual inspection
every 6 months
07.1.50
Flow meter
Visual inspection
monthly
07.1.55
Solenoid valve
Visual inspection
monthly
Piping
Visual inspection
weekly
Assembly: Ambient Air Monitoring
34.1.10
Ozone Sensor
Check
Sensor replacement
every 6 months
every 6 months 2)
Assembly: Electrical Components / Electrical Cabinet
Fan
Visual inspection
weekly
Filter mat
Filter mat cleaning,
replacing filter mats,
if necessary
at least
every 6 months
1)
Electrical
components
Checking all
connections
for tightness.
annually
Assembly: Safety equipment
Warning signs,
pictographs
Visual inspection
weekly
1) dependent on ambient conditions
2) The ozone sensor includes a self-test. If an earlier sensor change is
necessary, this is shown in the display of the instrument ("Check sensor"),
refer to the manual of the manufacturer
.