Manual Ozone Generating System
SMOevo
PLUS
System Description
Manual_SMOevoPLUS_eng_01.2019.doc
page 53 of 179
•
The setting of the temperature transmitter must not be
changed at any time!
07.1.30
Drain valve
To vent all air from the water cooling system during
commissioning or in case of maintenance or service. Must be
fully closed during normal operation.
07.1.35
Butterfly
valve
Customer interface for cooling water return.
Option: Converter Cooling SMOevo 610 - SMOevo 860
From type SMOevo
PLUS
610 on, in addition to the ozone generator, the converter is water
cooled too.
07.1.20
Butterfly
valve
To be throttled to the extent that a sufficient amount of cooling
water is guaranteed for the converter cooling.
07.1.45
Ball valve
Must be fully open.
07.1.60
Ball valve
07.1.50
Flow meter
To display the flow. The flow meter is equipped with a limit-
indicating contact which switches off the system and triggers a
fault message if the value falls below 2l/min (set point =
4l/min).
07.1.55
3- way
mixing valve
The 3-way mixing valve allows a continuous flow through both
cooling circuits, and thus a continuous temperature control.