37,048.48:
PEST - Power 12 volt under limit.
37,049.40:
PEST - Power supply -12 volt over limit.
37,050.41:
PEST - Power supply -12 volt under limit.
37,051.42:
PEST - Power supply current over limit.
37,052.43:
PEST - Power supply current under limit.
37,053.44:
PEST - Power 50 volt over limit.
37,054.45:
PEST - Power 50 volt under limit.
37,055.46:
PEST - Power supply -50 volt over limit.
37,056.47:
PEST - Power supply -50 volt under limit.
37,057.48:
PEST - Power 15 volt over limit.
37,058.40:
PEST - Power 15 volt under limit.
37,059.41:
PEST - Power supply -15 volt over limit.
37,060.42:
PEST - Power supply -15 volt under limit.
37,061.43:
PEST - Power supply high switch will not activate. 12, 15, and 50 volt
missing. This may be due to a short or disconnected power supply reset line.
37,062.44:
PEST - Vss measurement too low. The printhead power cable may be
disconnected.
37,063.45:
PEST - Vpp measurement too low. The printhead power cable may be
disconnected.
Troubleshooting Procedure
Step
Questions and Actions
Yes
No
1
1.
Run the Voltages check test.
2.
Did the test pass?
Go to Step 2.
Replace the
electronics
module.
2
1.
Check the printhead power cable.
2.
Is the wiring damaged or not connected?
Reseat the
wiring.
Replace the
electronics
module.
Summary of Contents for WorkCentre C2424/DX
Page 1: ...WorkCentre C2424 copier printer Service Manual...
Page 2: ......
Page 16: ...xii WorkCentre C2424 Copier Printer...
Page 24: ...xx WorkCentre C2424 Copier Printer...
Page 92: ...2 48 WorkCentre C2424 Service Manual...
Page 300: ...6 14 WorkCentre C2424 Service Manual...
Page 374: ...8 64 WorkCentre C2424 Service Manual s2424 214 Back Frame...
Page 379: ...9 Section Parts Lists In this chapter Serial Number Format Using the Parts List Xerox Supplies...
Page 431: ......
Page 432: ...604E13990...