Error Messages and Codes
3-29
13,200.41:
The right jetstack heater is too hot.
13,202.43:
The right jetstack heater took too long to reach its setpoint.
13,259.46:
The right jetstack thermistor circuit is open.
13,261.48:
The right jetstack thermistor circuit is shorted.
13,263.41:
The right jetstack thermistor returned a bad reading, or the reading was
corrupted by ESD.
Troubleshooting Procedure
Step
Questions and Actions
Yes
No
1
1.
Verify that the ambient temperature of the
room is within the system’s optimal
environmental specification (see "System
Environmental Specifications" on
page 1-14).
2.
Is the room too cold or too hot?
Advise
customer of
specification
requirements.
Go to Step 2.
2
1.
Ensure the ground integrity of the system
(see "Ensuring Ground Integrity" on
page 4-73).
2.
Are all components grounded properly?
Go to Step 3.
Resolve ground
integrity.
3
1.
Run the Right Jetstack Temperature test.
2.
Did the test pass?
Go to Step 4.
Replace the
printhead.
4
1.
Check and reseat all wiring to the printhead.
2.
Did this correct the problem?
Complete.
Replace the
printhead.
Summary of Contents for WorkCentre C2424/DX
Page 1: ...WorkCentre C2424 copier printer Service Manual...
Page 2: ......
Page 16: ...xii WorkCentre C2424 Copier Printer...
Page 24: ...xx WorkCentre C2424 Copier Printer...
Page 92: ...2 48 WorkCentre C2424 Service Manual...
Page 300: ...6 14 WorkCentre C2424 Service Manual...
Page 374: ...8 64 WorkCentre C2424 Service Manual s2424 214 Back Frame...
Page 379: ...9 Section Parts Lists In this chapter Serial Number Format Using the Parts List Xerox Supplies...
Page 431: ......
Page 432: ...604E13990...