Page 2 Configuration Options
IO preset
This options provides several QC system selections. All the necessary
RS-232 interface parameters are automatically set when a predefined I/O
preset is selected. A “CUSTOM” preset is available which allows you
manually set all available I/O options. Below is a chart that contains all
available I/O presets and their parameter settings.
NOTE:
Certain parameters are mandatory for the I/ O preset and cannot be
changed. They are labeled with an “L” for locked. Other parameters are not
considered mandatory and are labeled with a “U” for unlocked. Parameters
labeled "#" must be set manually to ensure proper use. Finally, parameters
that remain unchanged from previous settings—and can be changed—are
shown as an asterisk (*).
I/O Preset
RCI PIN5 XON DPT COMP ALF DEL AXMT REF
BAUD
REPORT
Off
*
*
On (L)
On (L)
On (U)
Off (L)
Off (U)
On (U)
*
SPRD-SHT
* * * *
Off
(L)
* *
On
(L)
* *
k:TNetA
Off (L)
Off (L)
Off (L)
Off (L)
On (L)
On (L)
On (L)
On (L)
Off (L)
300(L)
k:TNetXT
Off (L)
CTS(L)
Off (L)
Off (L)
On (L)
On (L)
Off (L)
On (L)
Off (L)
*
K:C.A.P.
Off (L)
CTS(U)
Off (L)
Off (U)
On (U)
On (U)
Off (L)
On (L)
*
9600(L)
k:SYS25-75 Off (L)
CTS(L)
Off (L)
Off (L)
On (L)
On (L)
Off (L)
On (L)
*
*
f:TECOM
Off (L)
Off (L)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (L)
1200(U)
c:I/O#1
On (L)
Off (L)
Off (L)
Off (U)
On (U)
On (U)
On (U)
On (L)
*
9600(L)
c:I/O#2
On (U)
Off (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
On (U)
*
9600(U)
MITSY#1
Off (U)
Off (U)
Off (U)
Off (L)
Off(L)
Off(L)
Off (U)
On (U)
*
300(L)
MITSY#2
Off (L)
Off (L)
On (U)
Off (L)
Off(L)
Off(L)
Off (L)
On (L)
Off (L)
300(U)
NORITSU
Off (L)
CTS(U)
Off (L)
Off (L)
On (L)
On (L)
Off (L)
On (L)
Off (L)
2400(U)
n:QSSnet
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (U)
2400(U)
n:Micro
* * * * * * * * * *
kn:Net
TTL (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
Off (U)
On (U)
2400(U)
a:LC2000
Off (U)
Off (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
On (U)
Off (U)
1200(U)
CUSTOM
# # # # # # # # # #
Windense On (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
On (U)
On (U)
9600 (U)
Kodatel
On (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
On (U)
On (U)
9600 (U)
Sienna
On (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
Off (U)
On (U)
Off (U)
4800 (U)
k: (Kodak), f: (Fuji), c: (Copal), kn: (Konica), n: (Noritsu), a: (Agfa)
NOTE:
Setting the I/O preset to “n:Micro” changes the menu structure of the
instrument making several menu items unavailable.
Page 2a Configuration Options
RCI (Remote Control Interface)
Controls the ability of the instrument to be operated remotely. Available
settings are: OFF, ON, TTL.
•
OFF - sets the instrument into a receive mode at which time the instrument
receives data.
•
ON - enables data to be received via RCI command.
•
TTL (Time Tagged Log) - causes all data received into the serial port to be placed
into the log buffer with a time stamp.
PIN5
Determines the status of the handshaking input on Pin 5 of the RS-232 I/O port.
Pin 5 may be interpreted as BUSY, CTS (clear-to-send), or OFF (ignored).
XON
When set to On (XON), this enables bi-directional transmit On/Off protocol.
Summary of Contents for 891
Page 1: ...891 892 A U T O M A T I C S T R I P R E A D I N G D E N S I T O M E T E R S Operation Manual...
Page 2: ......
Page 4: ......
Page 10: ...I N T R O D U C T I O N vi...
Page 34: ...S E C T I O N T H R E E 3 8...
Page 46: ...S E C T I O N F O U R 4 12...
Page 52: ...S E C T I O N F I V E 5 6...
Page 58: ...S E C T I O N S I X 6 6...
Page 60: ...S E C T I O N S E V E N 7 2...
Page 66: ...S E C T I O N E I G H T 8 6...
Page 68: ...A P P E N D I X A A 2...
Page 73: ...D 1 A P P E N D I X D Parts List and Packaging Drawings Parts List...
Page 74: ...A P P E N D I X D D 2 Packaging Drawing...
Page 78: ...A P P E N D I X E E 4...
Page 79: ......