Error messages
International L – edition: 17.02.2006
79
23.4
The state ’OUT OF ORDER’
In case of a fault the LCD display shows "OUT OF ORDER!"
(message 12).
With an empty text memory the state "Out of order!" can only
be recognised by the missing decimal point com-pared to the
state "Machine accepts 0.05 - 2.00 EURO"!
After you have entered a valid selection number (for exam-
ple 11 but not 99), an error code is displayed (message 15).
The meaning of the error codes and how to clear them are
all explained on the following pages.
After clearing the fault you also have to erase the error code,
which you can perform by pressing button S until "MA-
CHINE ACCEPTS 0.05 - 2.00 EURO" is displayed (see also
).
When you remove the error and leave the service program
the error code is cancelled automatically.
When an uncleared fault is involved, the control unit re-dis-
plays the message "OUT OF ORDER!".
23.5
The LCD display does not show anything
Reason:
With message 0, 9 or 12 (standby and 'out of or-
der' messages) indicating that blank characters
have been programmed by mistake.
Remedy:
!
Keep pressing button P.
!
Touch button S once.
!
Keep pressing button 0 as many times as
needed until the display shows 00-01-00 (indi-
cating that the message 0 has been erased
completely).
To check:
Exit the service program whereby the display
shows: "00.00".
Enter the new text messages (
) or programme with software IVC-Pro-
grammer (
OUT OF ORDER
Text memory factory preset
0000
’Out of order’ text memory empty
00.00
’In operation’ text memory empty
Difference
ERROR CODE: 77
Text memory factory preset
77
Error message if text memory empty
LCD display only lights
Possible appearance of message 0.
Message 0 deleted.
Message 0
15 lines total
10 characters in first line
No characters visible,
space characters in
the line