Initialisation of an IVC unit after replacement
International L – edition: 17.02.2006
68
Press button D again, the blinking character changes one digit
to the left. Press until display shows
Press button D again, the blinking character changes one fur-
ther digit to the left. Press until display shows
Press button D again, the blinking character changes one digit
to the left. Press until display shows
(If you hold key P counts backwards)
Press key P - hold it - and press button 1, the left side blinking
stops. Display shows
Apply the same procedure in service program 15, button 2, 5
and 9 which are for the different coin systems as shown in the
following table.
For machines with
button 1
button 2
button 5
button 9
!
coin system MDB
7620
3107
0020
0060
!
coin system MDB and vend light gate
7320
3107
0020
0070
!
coin system MDB and SmartWaiter (elevator system)
7620
3107
0020
4060
!
coin system Executive Standard
3480
3107
0000
0060
!
coin system Executive Standard and vend light gate
3180
3107
0000
0060
!
coin system Executive Standard and SmartWaiter
(elevator system)
3480
3107
0000
4060
!
coin system acc. to BDV standard
3480
3107
9000
0060
!
coin system acc. to BDV standard with vend light gate
3180
3107
9000
0070
!
electronic coin acceptor (ECA) and 5 tube changer
3660
3107
0000
0060
!
electronic coin acceptor (ECA) only (exact money)
3460
3107
0000
0060
!
CCI-System
3480
3107
1000
0060
SELECTION:
01 =0020
SELECTION:
01 =0620
SELECTION:
01 =7620
SELECTION:
=7620