![Wurlitzer International L Operating Instructions Manual Download Page 75](http://html1.mh-extra.com/html/wurlitzer/international-l/international-l_operating-instructions-manual_1000985075.webp)
Service programs (in tabular form)
International L – edition: 17.02.2006
75
21.2
Coin systems according to BDV standard
Service
program
Function
Call with button
with P
01
!
Vend counter per compartment
!
Change giver runs
selection buttons
return button
reset
reset
02
!
Selections if column empty
only for cigarette machines!
03
!
Total vends (items)
!
Vends made with ’Please insert exact mony’
!
Credit not clear
!
Manually filled money
0
1 - 2
5 - 6
7 - 8
reset
reset
reset
reset
04
!
Manually gathered change
!
Total of change paid in excess
!
Number of power on/off
!
Number of price memory copies
!
Reset of statistical counters
1 - 2
3 - 4
6
7
8
reset
reset
+0000 reset
reset
reset
05
!
Turnover
!
Cash box contents
!
Change paid out
!
Money into tubes
!
Customer number
!
Safety number
1 - 2
3 - 4
5 - 6
7 - 8
9
0
NON
RESETABLE
‘‘
’’
programme
06
!
Turnover
!
Cash box contents
!
Change paid out
!
Money into tubes
1 + 2
3 + 4
5 + 6
7 + 8
programme
programme
programme
07
!
Display test, display of software version
!
Each change giver motor starts once
!
Pay out of single tubes
!
Coin acceptance for 5 seconds with indication of coin
channel
!
Motor test of each spiral
!
Access to service programs 11 - 17
1
2
P + 2, then 1 - 3
6
7
P + 8
STOP with button C
08
!
Price programming
!
Max. change
selection buttons
return button
reset
09
!
Free button column allocation
only for cigarette machines!
10
!
Vend options:
!
00 = normal
!
01 = free vend
!
04 = parallel
!
08 = alternate
!
80 = disable
selection buttons
programme