background image

Operation with coin systems according to Executive standard

International L  – edition: 17.02.2006

38

10.5

Reset of all counters - service program 04, button 8

Press key S four times, display shows

Press selection button 8 and hold it, display shows

Press key P. The digits 08 disappear.

All statistics counters pertaining to service programs 1 to 4 and
6 are reset. 
The counter for current supply interruptions (service program 4, button 6) and that for the tube stock-
taking in service program 6, button 7/8 are not reset. The data has to be reset separately. The reset
of the counter for current supply interruptions is described in 

see chapt. 14.1 on page 48

.

ATTENTION! In case infrared data transfer according to BDTA standard is activated these counters
can not be reset manually. This will be done by the BDTA terminal 

(see page 74 and page 77

).

Finally leave the service program (

see page 20

).

11

Operation with coin systems according to Executive 
standard

When applying one of these coin systems, the data relating to the maximum value of change and to
the vending options have to be entered in the respective coin system.

The programming steps are described in detail in the manuals supplied by the coin system manufac-
turers. Use the coin slot to insert not less than 20 coins of each denomination into the change giver
tubes.

To delete the credit please refer to the manufacturers operating instructions.

If the coin system does not work with the IVC unit (error code77), a re-programming of the IVC unit
may be necessary (

see chapt. 20 on page 67

).

Test vend:

When you wish to make a test vend, push
button "Credit" of the IVC control unit. The
test vend has no effect on the vend counters. 

04 COUNTER
   RESET

SELECTION:
 08 =9999

SELECTION:
    =9999

test
vend

Summary of Contents for International L

Page 1: ...R International L Operating Instructions GB 16 14 10 11 12 13 16 17 15 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 R 1 2 5 DM INTERNATIONAL L INTERNATIONAL L 7 ...

Page 2: ......

Page 3: ...chine into Operation 18 4 1 Connection and First Steps 18 5 Programming of the machine 19 5 1 The programming terminal 19 5 2 The state IN OPERATION 19 5 3 The service programs overview 20 5 4 How to leave the service program 20 6 Programming of vend prices 21 6 1 Different selections with different prices 21 6 2 Several selections with identical prices 21 7 Machine test service program 07 23 8 Op...

Page 4: ...ll up statistical data service program 05 06 36 10 4 Individual counter reset 37 10 5 Reset of all counters service program 04 button 8 38 11 Operation with coin systems according to Executive standard 38 12 Operation with coin systems according to BDV standard 39 12 1 Filling the change tubes 39 12 2 Display PLEASE INSERT EXACT MONEY 39 12 3 Manual coin dispense service program 07 39 12 4 Dispens...

Page 5: ...How to programme the text memory applying PC 59 16 Statistic print outs 60 16 1 How to connect the printer 60 16 2 Print out of statistics 61 16 3 Print out of set commodity prices 61 17 Statistic print out MDB 62 18 Statistic print out NRI Simplex 5 or Executive 64 19 Statistic print out BDV standard 65 20 Initialisation of an IVC unit after replacement 67 20 1 Preparation for initialisation 67 2...

Page 6: ...t 78 23 3 Extension cable 78 23 4 The state OUT OF ORDER 79 23 5 The LCD display does not show anything 79 23 6 List of error 80 24 Technical Data 84 24 1 Type Plate Signboards 84 24 2 Technical Electrical Data 84 24 3 Fuse on the IVC2 Control Unit 84 25 Technical Appendix 85 25 1 Filling Plan International L 85 25 2 Connecting Diagram 86 26 Declarations of Conformity 87 ...

Page 7: ...hanged Strong metal keyboard with integrated return button for motor driven change return Illuminated brands and price labels Display indicating that the columns are empty Infrared sensor for reading statistical data by means of a mobile data capture device You can purchase this device separately at specialized distributors the infrared sensor is the interface which is necessary for reading the da...

Page 8: ...ard Change giver over a separate 5 tubes change giver Bill acceptor Change return with hopper 1 2 Dimensions Weight and Capacity International L weight net 140 kg 308 6 lbs selections 27 to 35 max capacity 756 705 mm 27 5 in 617 mm 24 1 in L 140 mm 430 mm 16 8 in L 600 mm 23 4 in L 1293 mm 50 4 in 530 mm 20 7 in 1365 mm 53 2 in 1287 mm 50 2 in 355 mm 13 9 in 475 mm 18 5 in 625 mm 24 4 in 5 5 in ...

Page 9: ... the bottom of the vending machine For short distances the vending machine can be transported by means of these wheels on even surfaces without obstacles 2 2 Package Contents The package contents includes Keys for the vending machine The keys are placed on the front of the vending machine in the product delivery bin Operating instructions Place the operating instructions in the lower part of the v...

Page 10: ...ng machine can be opened without any problems Use the square plastic screws to adjust and to fix the vending machine Be sure that the vending machine is placed on an even surface 3 Take the bag with the accessories out of the cash box of the vending machine 4 Pass the power cable through the round hole on the rear side of the vending machine then close the hole by means of the cover The cover is p...

Page 11: ...ion of pictures In order to exchange the picture follow the steps below 1 Open the door of the vending machine 2 Open the inner door by pulling the red handle 3 Unscrew the thumb screw and turn the glass clamp 4 Remove the acrylic glass pane by pulling it upwards 5 Take the acrylic glass pane as model for cutting the new picture 6 Exchange the picture 7 Replace the acrylic glass pane and install i...

Page 12: ...olumns between the columns 22 to 37 you have to adjust the assignment of product selection and motor again selections maximum 35 capacity maximum 510 packs middle column 9 x 63 mm 2 5 in max 597 mm 23 3 in rear column 11 x 63 mm 2 5 in max 693 mm 27 0 in door column 7 x 63 mm 2 5 in max 451 mm 17 6 in standard 6 long columns 6 short columns 225 mm 8 8 in 225 mm 8 8 in 685 mm 26 7 in 30 packs 560 m...

Page 13: ...nd pull it upwards until the locking is released 4 Remove the motor of the product column which should be dropped To do so loosen the cable connection at the motor pull the locking lever at the motor and remove the motor 5 Move the divider according to the width of the products and press the divider downwards until the locking locks in place 6 Adjust the assignment of product selection and motor a...

Page 14: ...hes The columns 20 to 24 have a height of 430 mm 16 8 inches For long and standard packs you have to position the adjusting lever as shown in the picture below In case you want to vend short packs from the short columns you have to insert the adapter rail from the accessories bag see picture RH side Setting for long packs without adapter rail install adjusting lever in rear position standard packs...

Page 15: ...oving the square see page 16 By combining the two possibilities it is possible to adjust the clearance height for all common width of packs The following pages will help you with this task Width of packs mm Position of the motor Square for reducing the clearance height 10 mm 0 4 in to 18 mm 0 7 in motor installed in upper position square for reducing the clearance height 18 mm 0 7 in to 26 mm 1 0 ...

Page 16: ...Upper position lower slot clearance height 18 mm 0 7 inches to 26 mm 1 0 inches Lower position upper slot clearance height 32 mm 1 3 inches to 40 mm 1 6 inches Adjusting the Clearance Height by Moving the Square Positions The squares for reducing the clearance reduce the clearance of the corresponding product column by 8 mm 0 3 inches if they are screwed to the adjusting levers The accessories con...

Page 17: ...verted into short columns and the short columns 32 to 37 can be converted into long columns see page 17 Follow the steps below in order to convert short columns into long columns and vice versa NOTE Detailed information about installing and removing the dividers motors etc can be found in chapter Adjusting Product Columns see page 13 Remove the dividers of the product columns which should be conve...

Page 18: ...e assignment of product product column down in the filling plan see page 85 3 Be sure that the pack size of the selling products corresponds to the adjustments of the product columns If necessary adjust the product columns again Adjusting the width of a product column see page 13 Adjusting the depth of a product column see page 14 Adjusting the heigth for passage of a product column see page 15 4 ...

Page 19: ...ted in the display by message 0 or message 9 in case the change tubes are not yet filled see chapt 15 7 on page 54 If the text memory is empty message 0 will appear programming is still possible You can call up 17 service programs with the programming terminal Example service program call Press button S once Service program 01 is reached see arrow Text 01_VENDS ___PER_SELECTION is preset from fact...

Page 20: ...me 60 seconds after that the machine automatically reverts to standard vending mode Section 1 Service programs 1 10 display of statistics sales machine tests programming of vend prices vend modes selection options To call up Press key S until the desired program is found If you wish to return to any previous service program keep key P pressed and press key S service programs will run back wards Se...

Page 21: ... Proceed by pressing key P etc 6 2 Several selections with identical prices 1 Push key S to call up service program 08 until display shows 2 Enter the desired selection number e g 10 The current vending price for the said product is displayed e g 1 00 EURO 3 To programme a different price keep key P pressed dis play shows 4 Then enter the new price e g 1 50 EURO applying all four digits 0 1 5 0 Th...

Page 22: ...ot touch key C this act auto matically cancels the current new price just entered 8 When price programming is completed leave the service program see page 20 Price check Press any selection number the current vending price flashes for a few seconds Press button C to proceed to the next compartment Repeat as many times as needed ...

Page 23: ...button C Press button 6 Coins accepted now for some 5 seconds When inserting the coins the coin channel involved is displayed To complete the job press key C Press button 7 Motor test All available selections are operated once This test tries to run also all selections which are not available like disconnected motors or trays and disables them if noted The same applies after adding trays the relev...

Page 24: ...ling plan With that you can see which button belongs to which col umn in case of single reset or reprogramming 8 1 Following button column allocations are possible 8 1 1 One selection drives one column with different number Example When 10 is selected column no 20 delivers Programming 1 Press button S until display shows 2 Enter selection 10 display shows 3 Press button P hold it display goes dark...

Page 25: ...regular vending Programming 1 Press button S until display shows 2 Enter selection 10 display shows 3 Press button P hold it display goes dark and enter the figures 1 0 1 2 Display shows Finally press button S until display shows Ready 8 1 3 Several selections driving one column Example If one of selections 11 12 or 13 is made always column no 13 delivers 1 0 10 11 12 selection column 09 1010 1012...

Page 26: ...8 1 4 Several selections driving alternately same number of columns i e columns deliver evenly no matter which column was selected Example Columns no 14 to 18 should deliver consecutively no matter which column between 14 and 18 was selected Programming 1 Press button S until display shows 2 Enter selection 14 display shows 3 Press button P hold it display goes dark and enter the figures 1 4 1 8 d...

Page 27: ...n example 8 1 4 Reset can be done without cancellation of programming done in part 8 1 1 8 1 2 and 8 1 3 1 Reset call up service program 09 2 Enter selection 14 display shows 3 Press button P hold it display goes dark Enter the fig ures 1 4 1 4 display shows 4 Press button C display shows 5 Enter selection 15 display shows 6 Press button P hold it display goes dark Enter the fig ures 1 5 1 5 displ...

Page 28: ... column allocations in service program 09 1 Call up service program 09 display shows 2 Enter any selection e g 11 display shows 3 Press button P hold it display goes dark Enter 4 times figure 9 display shows first then 4 Press button C display shows Finally press button S until display shows Ready 09 1111 9999 1111 09 ...

Page 29: ...s Check machine configuration in service program 15 see chapt 20 on page 67 9 2 Display shows PLEASE INSERT EXACT MONEY If the coin tube containing the lowest denomination coins 0 05 EURO has insufficient stock less than some 15 coins the display shows PLEASE INSERT EXACT MONEY or MACHINE AC CEPTS 0 05 0 50 EURO message 9 If the coin tube containing the lowest denomination coins is filled with som...

Page 30: ...4 coins are collected from the second third or fourth tube NOTE Press key C to interrupt the collecting program To call it up again press key P hold it and press selection button 2 9 4 Programming max change service program 08 Press key S eight times display shows Press button R or enter selection 90 display shows maximum change e g 5 00 EURO For alteration press button P hold it and enter the des...

Page 31: ...ingle vend WITH obligation to buy Automatic return of change after a buy The money in serted can be used for one vend only Change returns au tomatically after delivery if below max change 5 Single vend WITH obligation to buy automatic return of change with possible loss of full change This is a single vend operation where change return is au tomatic after a vend but there is a possibility that the...

Page 32: ... disabled or coin is not used except of the lowest coin value 0 05 EURO it can not be disabled 09 Coin is accepted to the cash box even if the return tubes empty Programming Press the respective coin channel button press key P hold it and enter the desired option i e 80 Use two dig its as decribed above How to check Press key C display shows Press the re programmed button e g 1 the new option e g ...

Page 33: ...ying four digits Display shows Release button P Finally leave the service program see page 20 9 8 Number of coins to be accepted service program 14 You can program the maximum number of coins to be accepted before a vend Programming Press key P hold it press key S four times display shows Press button 7 which shows the current number of coins accepted e g Always one more coin than displayed will b...

Page 34: ...ice program see page 20 9 10 Programming of the bill input service programs 11 12 14 You can connect a bill acceptor which sends serial impluses according to accepted bill values to P8 of the IVC control unit NOTE For bill validators accepting different bills you have to programme the value of the lowest bill i e 5 00 EURO Bills of higher values will be simulated through a certain number of impuls...

Page 35: ...ption i e 09 in 2 digits display shows Release button P 9 10 3 Programming number of bills to be accepted before a vend service program 14 button 6 Running service program 12 you have to press button S twice display shows Press button 6 display for i e The RH number indicating that currently 50 1 bills will be ac cepted before a vend Programming Press button P hold it display shows Enter new numbe...

Page 36: ...imes display shows Press selection button 0 which displays the total vends of all se lections since the latest reset for example the digits 2560 means that 2560 products have been sold Resetting Press key P hold it and enter the digits 0000 Finally leave the service program see page 20 10 3 How to call up statistical data service program 05 06 The information of service programs 05 and 06 are disp...

Page 37: ...shing the corresponding button only press key P which sets the display to 0000 Complete the process by pressing key C Then proceed to the next counter Please notice that the statistics counters take two displays one for the lower and the other for the higher figures and that the displays have to be individually reset not resetable resetable general reset possible Total sales SP 5 button 1 2 SP 6 b...

Page 38: ...anually This will be done by the BDTA terminal see page 74 and page 77 Finally leave the service program see page 20 11 Operation with coin systems according to Executive standard When applying one of these coin systems the data relating to the maximum value of change and to the vending options have to be entered in the respective coin system The programming steps are described in detail in the ma...

Page 39: ...CHINE ACCEPTS 0 10 0 50 EURO or MACHINE ACCEPTS 0 05 2 00 EURO is displayed call up service programs 1 to 10 push key S ten times and check machine configuration see chapt 20 on page 67 12 2 Display PLEASE INSERT EXACT MONEY If the tube containing the lowest denomination coin is not sufficiently full then the display shows PLEASE INSERT EXACT MONEY or MACHINE ACCEPTS 0 05 0 50 EURO message 9 If th...

Page 40: ...vice program 08 button R Press key S eight times display shows Press button R or enter selection 90 display indicates current maximum change To change the sum of money press key P hold it and enter the desired amount in four digits e g 10 00 EURO enter 1000 which is displayed Finally leave the service program see page 20 12 6 Programming maximum coin insertion service program 11 button 1 If the pr...

Page 41: ... one buy has to be made before the machine returns the change when you press return but ton 3 Single vend WITHOUT obligation to buy automatic return of change The functions are the same as described in item a with the exception that the change is returned automatically after the first vend Please pay attention to the maximum change sum The machine can also be used as a change giver The BDV audit f...

Page 42: ...on display e g When you wish to change the reading press button P hold it and enter the new option Use four digits e g 0012 which gives the display How to check the present status Press key C display shows service program Press button 5 display shows the new option e g Finally leave the service program see page 20 NOTE Applying button 6 in service program 11 you can disable coins in extended coin ...

Page 43: ...ns E 1 00 EURO and F 2 00 EURO are accepted when the display indicates PLEASE INSERT EXACT MONEY 1 00 EURO coin coin E 0016 2 00 EURO coin coin F 0032 New configuration 0048 Programming Press key P hold it and press key C seven times display shows Press button 3 display shows the current option When you want to change the option press key P hold it and enter the new option in four digits e g 0 0 4...

Page 44: ...coin return tubes will be applied to indicate the Empty message Programming Press key P hold it press key S seven times display shows Press selection button 2 display shows current option e g 1 no coin offset 2 Empty message appears when the actual number of coins in tube A or B and C is less than 15 Programming Press key P hold it and enter desired option NOTE With a 4 tube changer the tube D wil...

Page 45: ...s of all compartments service program 03 resetable Press key C three times display shows Press selection button 0 which displays the total sales sum of all product compartments since the last reset of counters e g 2560 2560 products have been sold Resetting Press key P hold it and enter the digits 0000 Finally leave the service program see page 20 13 3 Statistical data BDV standard service program...

Page 46: ...t see chapt 12 7 on page 41 and table on page 76 13 4 Individual resetting of counters When the sum concerned is displayed by pushing the respective button you only need to press key P to reset the counter The display is set to 0000 To complete the job press key C and proceed to the next issue Please remember that the statistics counters are displayed in two parts which means you have to reset bot...

Page 47: ...ts 08 disappear All statistical counters in service programs 1 to 4 and 6 are re set The counters for current supply interruptions service program 4 button 6 and for the tube stocktak ing in service program 6 button 7 8 are not reset The data has to be reset separately The reset of the counter for current supply interruptions is described in see chapt 14 1 on page 48 Finally leave the service prog...

Page 48: ...bers can be entered hold P and enter 4 digits over keyboard ATTENTION You can enter the number only once when the display is 0000 Once entered you can neither change nor delete the number 14 3 Security number in four digits service program 05 Call up service program 05 button 0 The IVC control unit is furnished with a battery buffered RAM IC2 for storing data like prices statis tics and options Th...

Page 49: ...splay may show the following You can enter any desired message by apply ing the selection buttons whose functions are indicated below Button 1 Calls up character font towards A backwards Button 2 Calls up character font towards Z forward Button 3 Returns to the previous line of a message stop on line 1 Button 4 Moves the cursor to the left within a line Button 5 Moves the cursor to the right withi...

Page 50: ...nter blank characters Keep pressing button 9 auto repeat until an exclamation mark is displayed in the cursor field First press button 1 and then key C Button 9 Moves the cursor to pre determined positions within the character font which makes the programming and locating of any character easier The following positi ons are defined 0 Numbers A Capital letters a Small letters MA Coin denominations ...

Page 51: ...ver at this time only the messages 00 22 and 31 46 will be used Example Message 00 indicates optional readiness in stand by mode MACHINE_ACCEPTS_0 05_ _2 00_EURO Message 12 indicates a fault Possible messages shown starting page 54 Head Control signs Special characters characters 0 A a MA AW K5 1 B b MC AT U5 2 C c MC AL W2 3 D d MD AS E2 4 E e ME AB S2 5 F f MF AN D2 6 G g MG EO D4 7 H h MH EO D8...

Page 52: ...ion erasure addi tion are also shown on this line provided that the changes are located within the area of the first 16 characters 15 5 Meaning of the place holders To display actual prices credits selections opera tion states etc so called place holders have to be inserted These parameters will be replaced with the actual numerical data during operation When programming you have to enter as many ...

Page 53: ...cimal point R5 Max change 4 figures decimal point MA Coin contact 1 4 figures decimal point MB Coin contact 2 4 figures decimal point MC Coin contact 3 4 figures decimal point MD Coin contact 4 4 figures decimal point ME Coin contact 5 4 figures decimal point MF Coin contact 6 4 figures decimal point MG Coin contact 7 4 figures decimal point MH Coin contact 8 4 figures decimal point MS Bill accept...

Page 54: ...um amount of change R5 8 Coin return in progress R5 9 Machine in stand by mode but change return empty 10 Too much credit change return impossible R5 U5 R5 MA MH MS 11 Credit is equal to 0 vend completed 12 Machine fault E2 13 Service program general D4 S2 E2 W2 14 Printer in operation 15 Fatal error machine out of order E2 16 Warning 17 Waiter key activated D2 NUMBER D9 COUNTER D2 D9 18 Operating...

Page 55: ...ng X4XX in service pro gram 15 with button 5 not for BDV systems 05 ANOTHER SELECTION 06 NOT_ENOUGH CREDIT_P5_____EURO 07 MAXIMUM_CHANGE R5_____EURO 08 TAKE_YOUR CHANGE 09 MACHINE_ACCEPTS 0 05_ _0 50 EURO PLEASE_INSERT EXACT_MONEY Display changes between MACHINE ACCEPTS 0 05 0 50 EURO and PLEASE INSERT EXACT MONEY 10 MAKE_NEXT SELECTION NO CHANGE 11 THANK_YOU 12 OUT_OF_ORDER 13 SELECTION W2__ _D4_...

Page 56: ...5 36 S2_RESETABLE _COUNTERS Service program 06 37 S2_TEST_PROGRAM Service program 07 38 S2_PRICE _PROGRAMMING Service program 08 39 S2_KEY_COLUMN _ALLOCATION Service program 09 Cigarette machines only 40 S2_VEND_OPTIONS Service program 10 41 S2_COIN_CHANNEL _SETTING Service program 11 42 S2_COIN OPTIONS Service program 12 43 S2_CHANGER_CHAN _SETTING Service program 13 44 S2_CHANGER _OPTIONS Servic...

Page 57: ...er I 6 Keep pressing button 2 until capital N is displayed in the cursor field Touch key C once to programme the said character 7 Keep pressing button 9 until the exclamation mark is in the cursor field Press button 1 once which brings the blank character into the cursor field Press button C to programme the blank character The capital N has now moved one position left in the computer memory 8 Pre...

Page 58: ...ocedure you can quickly and easily erase all the texts stored which reverts the memory to the basic state The LCD display only indicates an empty text memory see chapt 5 2 on page 19 and chapt 23 4 on page 79 Consequently programming of all service programs is possible It may be useful to erase the text memory of a machine with a LED display For example if the IVC control unit has been replaced Th...

Page 59: ...ming kit for MDB part no 0059430 IVC level adapter part no 0055413 Software IVC Programmer for MS Windows part no 0046333 Installations instruction TI WA 48d part no 0046334 The software IVC Programmer contents programming of messages setting of the four machine configuration codes which normally can be set in service program 15 buttons 1 2 5 and 9 price programming and vend options coin and chang...

Page 60: ...is fully charged Indicated by a perma nent lightning LED POWER after power on Also the settings of the DIP switches have to be checked Only switch 2 has to be switched on 16 1 How to connect the printer Connect the printer via the level adaptor 0060946 to the terminal P8 of the IVC con troller Then programme the value 3708 to the ser vice program 15 button 2 Proceed as fol lows Press button P hold...

Page 61: ...tton SEL once so that the LED goes dark Then press button LF to move the paper out 5 For a final reset of counters if required please refer to chapt 10 5 on page 38 or chapt 13 5 on page 47 BDV 16 3 Print out of set commodity prices 1 Keep pressing key S of the programming panel until the display shows 08 PRICE PROGRAM MING 2 Press button Print of the IVC unit The print out process starts display ...

Page 62: ...0005 0180 15 0021 0110 16 0003 0180 17 0003 0110 V P00008220 sales from compartment 1 V P Vend Price selection number no of vends price per selection 56 0002 0180 57 0003 0180 V P00002490 sales of compartment 5 RT 0209 total number of returned coins from tube 1 2 3 TOTAL 0146 total sales of all compartments data are NO COIN IN resetable 01 0010 0005 02 0050 0002 03 0100 0003 income number of accep...

Page 63: ... income cash change RET 00000300 change from tubes after vend AMT 00001000 amount of money in change giver tubes TOTAL SUMS VPR 00602218 total sales of machine INC 00002550 total income cash change RET 00000300 change from tubes after vend NOT resetable AMT 00001800 amount of money in change giver tubes MACHINE 0000 machine no only once programmable SAFETY 0525 safety number resetable ERROR 02 err...

Page 64: ...ales from compartment 1 V P Vend Price selection number no of vends price per selection 56 0002 0180 57 0003 0180 V P00002490 sales from compartment 5 RT 0209 total number of returned coins from change giver tubes 1 2 3 TOTAL 0146 number of vends of all compartments VALUES VPR 00001550 total sales of machine INC 00002550 total income cash change RET 00000300 total number of returned coins after ve...

Page 65: ...t by hand PRINT 0019 no of print out NO 37022720 serial number if programmed NO VEND PR NO number PR price 10 0021 0100 11 0018 0110 12 0007 0150 vends from compartment 1 selection 10 14 13 0003 0200 14 0019 0120 V P00006960 sales from compartment 1 V P Vend Price 20 0006 0350 21 0012 0160 22 0009 0280 vends from compartment 2 selection 20 24 23 0013 0080 24 0018 0110 V P00008220 sales from compar...

Page 66: ...00000 vends at message Insert exact money EXC EXaCt insertion DIV 00000000 discount vends DIV DIscount Vends MIS 00000000 miscellaneous credit MIS MIScellaneous MIN 00000000 money inserted in the service program MIN Manual INcome TOTAL SUMS VPR 00842150 INC 00836550 RET 00319000 AMT 00325600 MUT 00001120 same meanings as above but counters cannot be reset NON resetable OVP 00000000 EXC 00035240 DI...

Page 67: ...d it and press key S three times display shows When you press selection button 1 the display should show the configuration numbers in four digits after the equals sign e g 3480 code number for machines with Executive system If no configuration numbers are displayed when you press but ton 1 2 5 or 9 in service program 15 it is possible that no place holders have been programmed In this case you sho...

Page 68: ...erent coin systems as shown in the following table For machines with button 1 button 2 button 5 button 9 coin system MDB 7620 3107 0020 0060 coin system MDB and vend light gate 7320 3107 0020 0070 coin system MDB and SmartWaiter elevator system 7620 3107 0020 4060 coin system Executive Standard 3480 3107 0000 0060 coin system Executive Standard and vend light gate 3180 3107 0000 0060 coin system E...

Page 69: ...ress key P and hold it display is Enter the digits 9999 then display shows Release key P Finally leave the service program see page 20 20 4 Control of coin acceptance and change adjustment 20 4 1 Machines with MDB system Service program 14 Enter the maximum number of coins which should be accepted before a vend Programming Press key P hold it press key S four times display shows Press button 7 dis...

Page 70: ...key P hold it press key S seven times display shows Press button 1 display shows the current programmed sum e g 9000 90 00 Euro Alteration Press key P and hold it Display is Enter the new number in four digits e g for 20 00 EURO Finally leave the service program see page 20 Service program 8 Enter the maximum change Press key S eight times display is Press key R or enter selection 90 display shows...

Page 71: ...ge 23 Therefore Press key S until display shows Press button 7 Motor test starts All available selections are operated once This test tries also to run all selections which are not available such as disconnected motors or trays and disables them if noted The same applies af ter adding trays the relevant selections will be enabled The cur rent tested compartment is shown in the last two characters ...

Page 72: ...tistical counters 1 5 6 7 8 reset 0000 reset reset reset 05 Total sales Cash box contents Total change delivered Stocktaking coin tubes Customer number Safety number 1 2 3 4 5 6 7 8 9 0 NON RESETABLE programme 06 Total sales Cash box contents Total change delivered Stocktaking coin tubes 1 2 3 4 5 6 7 8 reset reset reset 07 Display test display of software version Each change giver motor starts on...

Page 73: ...on button 0 programme programme 9999 programme 12 Coin options per channel 01 Acceptance although change giver empty 08 Coin into cash box 80 Coin disable Bill options 08 Acceptance if change giver is filled sufficient 09 Acceptance although change giver empty 40 MDB bill acceptor 80 Bill disable Position of decimal point for place holders containing decimal point for example D5 P5 K5 MA 00 no poi...

Page 74: ...ith vend light gate 3480 Executive with SmartWaiter elevator system 3107 Printer port 3708 Citizen printer iDp3111 Machine options 0020 NRI Simplex 0 or MDB 0000 Executive system 0200 BDTA active 4710 formate text memory 4713 Snack reset Extended machine configuration 0020 Spiral single shut down 0060 Spiral single shut down LSCD display as from program version 4 51 no extra programming of the LCD...

Page 75: ... 1 2 3 4 6 7 8 reset reset 0000 reset reset reset 05 Turnover Cash box contents Change paid out Money into tubes Customer number Safety number 1 2 3 4 5 6 7 8 9 0 NON RESETABLE programme 06 Turnover Cash box contents Change paid out Money into tubes 1 2 3 4 5 6 7 8 programme programme programme 07 Display test display of software version Each change giver motor starts once Pay out of single tubes ...

Page 76: ... 6 0032 7 0064 to disable several coins add the single values BDV options Multivend 0001 Obligation to buy 0002 BDV Audit ON add 0004 BDV Audit OFF 0 add 0008 Credit card units add 0016 Values Token A B C 1 2 3 4 5 6 7 8 9 0 programme programme programme programme programme programme programme programme 12 Position of decimal point for place holders containing decimal point for example D5 P5 K5 MA...

Page 77: ...ation 0020 Spiral single shut down 0060 Spiral single shut down LCD display from program version 4 51 no extra programming of the LCD display is necessary you only have to enter 0020 selection button 1 selection button 2 selection button 5 selection button 6 selection button 9 programme programme programme programme programme 16 Waiter key only for cigarette machines 17 LCD display editor see chap...

Page 78: ... home position it will be powered up for 12 seconds During this time its number will be displayed 23 3 Extension cable An extension cable to facilitate the finding of any fault at the spiral motors of the trays is available un der part no 0005057 The cable enables you to check any tray outside the machine or to put a new tray into operation IVC Intelligent Vending Controller Fusibile 3 15A T Credi...

Page 79: ...lt is involved the control unit re dis plays the message OUT OF ORDER 23 5 The LCD display does not show anything Reason With message 0 9 or 12 standby and out of or der messages indicating that blank characters have been programmed by mistake Remedy Keep pressing button P Touch button S once Keep pressing button 0 as many times as needed until the display shows 00 01 00 indi cating that the messa...

Page 80: ...partment The other com partments can be used normally There is a possibility that some trays are not properly inserted Notice Error codes 02 to 09 only serve as warnings and they have no drastic effect on the func tions of the whole machine Error no Error Possible reason and remedy 11 No return signal from the return flap Return flap jammed or contact between flaps not closed 12 Return signal from...

Page 81: ...nuously active Change the coin validator Notice Error codes 40 to 48 mainly apply to machines with a Deutsche Wurlitzer GmbH escrow unit In case this error codes appear in machines with MDB systems you have to carry out data block transfer see chapt 9 9 on page 34 49 Bill input activated too long Only for machines with bill validator 50 One of the source drivers 1 to 8 IC 216 of the control unit h...

Page 82: ...nd correct if 250 times hig her than basic price 75 Fault in selection column allocation MDB coin acceptor gives no response 76 Data in coin validator Simplex 0 not corre sponding to programmed data in IVC MDB coin jammed This error code may appear after you have either replaced a coin validator or a complete coin mechanism To rectify call up service program 11 button 1 to re pro gramme Carry out ...

Page 83: ...onnection 230v 50cps 16amps power consumption 50watts weight empty 140 kg 308 6 lbs dimensions height width depth 136 cm 53 5 inches 70 5 cm 27 7 inches 60 cm 23 6 inches selections max 35 max capacity 756 noise level below 70 dB A illumination 1 fluorescent lamp 18 W length 590 mm 23 2 in diameter 26 mm 1 0 in important installation advice type plate of the vending machine serial number of the ve...

Page 84: ... 11 12 13 14 15 16 17 18 19 20 Selection Brand Price Middle Columns Brand Name Selection 21 22 23 24 25 26 27 28 29 30 31 Column No 21 22 23 24 25 26 27 28 29 30 31 Selection Brand Price Middle Columns Brand Name Selection 32 33 34 35 36 37 Column No 32 33 34 35 36 37 Selection Brand Price Door Columns Brand Name Selection 38 39 40 41 42 43 44 45 Column No 38 39 40 41 42 43 44 44 Selection Brand P...

Page 85: ...1 D2 D3 D4 D5 D6 D7 Interface LCD Anzeige Interface LCD Display 0033012 LCD Anzeige LCD Display P16a 16 1 28V DA DB DC D D A10 A11 A12 A13 A14 A15 Q R GND GND 5V gn ge or TR Thermo sicherung fuse 275V VDR 220V 240V AC Netzteil Power supply Münzsystem coin system supply 24V 24V DR ballast or br rt Fadenfänger String catcher IVC CONTROL UNIT K3 K4 X1 X2 X3 K1 K2 K3 K4 X1 X2 X3 X4 X5 X6 X7 Wahltasten...

Page 86: ...ctromagnetic compatibility Generic Emissions Requirements Compatibilité electromagnétique Norme générique emission EN 50082 2 Elektromagnetische Verträglichkeit Fachgrundnorm Störaussendung Electromagnetic Compatibility Generic Emissions Requirements Compatibilité electromagnétique Norme générique emission EN 60335 1 Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke Safety of...

Page 87: ......

Page 88: ...Wurlitzer GmbH Wurlitzerstraße 6 D 32609 Hüllhorst Tel 49 0 57 44 941 0 Fax 49 0 57 44 941 220 Email contact deutsche wurlitzer de Wurlitzer Registered Trademark of The Wurlitzer Company Part no 0049096 revision 4602 R ...

Reviews: