14.1
Counter, current supply interruptions - service program 04 (resetable)
Indicates the number of switch-ons and power failures, also change of fuse F1 - 3.15 A
Press key S four times, display shows
Then press selection button 6, display shows, e.g.
indicating that there have been eight breaks since the last reset.
Resetting:
Press key P and hold it, display is
Enter the digits 0000, display is
Finally leave the service program (
14.2
Entering customer number or machine number - service program 05
Applying service program 5, button 9, a customer or location number can be indicated. If this number
is displayed with 0 0 0 0, any desired four digit numbers can be entered (hold P and enter 4 digits
over keyboard).
ATTENTION! You can enter the number only once (when the display is 0000). Once entered, you
can neither change nor delete the number.
14.3
Security number in four digits - service program 05
Call up service program 05, button 0:
The IVC control unit is furnished with a battery-buffered RAM (IC2) for storing data like prices, statis-
tics and options. The security number is erased if either the RAM or the lithium battery is replaced or
removed for any period of time. An unchanged security number indicates that any relevant data, like
that registered by the non-resetable counters for turnover, is retained intact from the moment the ma-
chine was taken into operation.
14.4
Operating time - service program 15 (NOT resetable)
The hours of service can be displayed in 8 digits using service program 15, buttons 7 and 8.
Button 7 displays the higher figures and
button 8 the lower figures.
04 COUNTER
RESET
SELECTION:
06 =0008
SELECTION:
06=
SELECTION: