Error messages
International L – edition: 17.02.2006
78
23
Error messages
23.1
IVC unit
23.2
LED yellow on the IVC unit
23.2.1
CONTINUOUS yellow light:
Substained contact of a button. A selection button, the return button or buttons of the programming
terminal (except P) are closed continuously. If one of these contacts is closed longer than 7 seconds,
the machine is out of order.
23.2.2
BLINKING yellow light:
One or more motors are blocked. Which?
Exit the service program via level 10.
While the display counts backwards, each motor runs once.
If a motor is detected not in its home position it will be powered up for 12 seconds. During this time
its number will be displayed.
23.3
Extension cable
An extension cable to facilitate the finding of any fault at the spiral motors of the trays is available un-
der part-no. 0005057. The cable enables you to check any tray outside the machine or to put a new
tray into operation.
IVC
Intelligent
Vending Controller
Fusibile
3,15A
T
Credit Print
Motor
P3
LIGHTS as long as
- a selection button or
- the return button or
the buttons (S), (+) or
(D) are pressed.
BLINKS,
if a motor is blocked
or
if current was interrupted
after a selection
LIGHTS after input of
the first coin.
- plug P3 not connected
- fuse blown
- power supply unit defective.
LIGHTS continuously, if not:
Test credit
Starts print out
yellow LED
green LED
red LED