Error messages
International L – edition: 17.02.2006
80
23.6
List of error
ATTENTION! In case error numbers, which are not mentioned in following tables, appear in the dis-
play, the IVC control unit either has to be reprogrammed or to be exchanged.
Warning no.
Warning
Possible reason and remedy
02
One or several change tubes are empty.
Fill change tubes or, if no success,
change the coin system.
03
Hopper empty.
Either the hopper is empty or the indicator
sensor is defective.
04
05
06
07
08
Error in vend statistics memory,
Error in empty vend statistics memory,
Error in memory for prices and cashox
contents,
Error in price memory but restored by
copy,
Error in resetable vend memory
The statistics counters may show wrong
readings. If such messages appear fre-
quently, it indicates that the machine has
been switched on or off during a vending
process. See service program 04,
09
Return signal from vend motor missing af-
ter a selection.
One or several motors have an open cir-
cuit. Any such commodity compartment is
automatically blocked (by the control
unit), which makes it impossible to buy
from that compartment. The other com-
partments can be used normally.
- There is a possibility that some trays are
not properly inserted. -
Notice
: Error codes 02 to 09 only serve as warnings and they have no drastic effect on the func-
tions of the whole machine.
Error no.
Error
Possible reason and remedy
11
No return signal from the return flap.
Return flap jammed or contact between
flaps not closed.
12
Return signal from return flap too long.
Return flap open more than 5s or jam-
med, contact between flaps not opening
after return signal.
13
No return signal from the cash flap.
Cash flap jammed or contact between
flaps not closed.
14
Return signal from the cash flap too long.
Cash flap open more than 5s or jammed,
contact between flaps not opening after
return signal.
Notice
: Error codes 11 to 14 only apply to machines with a Deutsche Wurlitzer GmbH escrow. In
case they are displayed in machines without escrow, you have to check configuration.
15
Machines without vend light gate:
IVC unit has no correct configuration after
change or lost data for Multi.
Initialisation of IVC necessary. If fault
code re-appears frequently check battery
voltage for RAM supply (>2,8V) on IVC or
battery has an intermittent contact.
15
Machines with vend light gate:
cash pulse longer than 5 sec.
Check light gate and change, if neces-
sary.