![Wurlitzer International L Operating Instructions Manual Download Page 57](http://html1.mh-extra.com/html/wurlitzer/international-l/international-l_operating-instructions-manual_1000985057.webp)
The LCD display
International L – edition: 17.02.2006
57
15.9
Programming example
In stand-by mode (message 00) the text "
IN OPERATION
" should be displayed.
1.
Keep pressing key P of the programming terminal while
touching key S once. The upper line of the display (edi-
tor) may show the following.
This indicates that the actual message 00 comprises
one line with 15 characters.
2.
Erase the characters by keeping button 0 pressed until
the display is
The text to be entered comprises 11 characters and 1
blank one. As earlier described, one line can have a
maximum of 16 characters. To have the text in the middle of the display, enter two blank char-
acters at the beginning of the line.
3.
Keep pressing button 9 until you have the exclamation
mark
!
in the cursor field.
4.
Press button 1 once, which makes the character in the
cursor field vanish. Now enter the two blank characters
by pressing key C twice. The display is now
5.
Press button 9 twice, which brings the capital A into the
cursor field. Keep pressing button 2 until character
I
is
displayed in the cursor field. Now press key C to pro-
gram the character
I.
6.
Keep pressing button 2 until capital
N
is displayed in the
cursor field. Touch key C once to programme the said
character.
7.
Keep pressing button 9 until the exclamation mark (!) is
in the cursor field. Press button 1 once, which brings the
blank character into the cursor field. Press button C to
programme the blank character. The capital
N
has now
moved one position left in the computer memory.
8.
Press button 9 twice, which brings the capital A into the
cursor field. Keep pressing button 2 until the capital
O
is
on display in the cursor. To programme the said charac-
ter, press button C. The display is
9.
Push button 2 once to have the capital P in the cursor
field. To enter the character into memory, press key C.
The display is
We have, so far, produced the characters IN OP. Pro-
ceed in the manner described above to produce the rest of the characters. Use button 2 to go
forwards and button 1 to go backwards in the alphabetic order. Always complete the job by
pressing key C.
After the last data input the display should show
The 2 space characters on the right text side don't have
to be programmed. Press key S once to exit the service
programme, message "IN OPERATION" is displayed.
00:01-15= > <
00:01-00= > <
00:01-00= > !<
00:01-02= > <
00:01-03=I> I<
00:01-04=IN> N<
00:01-05=N> <
00:01-06=O> O<
00:01-07=OP> P<
00:01-14=ON> N<