Page 33
How Do I Decode and Monitor a Single Dolby Bitstream?
A single Dolby bitstream from the SDI or AES inputs may be monitored
continuously. The bitstream itseL doesn't have to be displayed on the Main Screen
meters. You may also monitor the Dolby metadata continuously.
Note:
The AMP2-16V must contain the optional Dolby decoder card in order to
decode a Dolby bitstream.
Setting up continuous Dolby bitstream monitoring is a two-step process, first
setting up the Decoder card and then setting up the monitoring channels. The first
step involves configuring the Dolby decoder card:
Configuration Selection
Menu
Main Screen
Menu
Audio
Processors
Audio Processor Card Menu
Dolby
Dolby Decoder
Configuration Menu
Figure 3–11: Dolby Decoder Configuration Menu
Dolby Decoder Configuration Menu
Save / Exit
Help
Cancel
Decoder Source
Pro-16 Mode
Channel
Dolby E
Program
Slot 1 (AES
In) Pair 1
Channel 1
Program 1
Decode
Aux Pair
DRC Mode
All formats
LtRt Downmix
Line Mode
Coding Mode
1/0 (C)
Bitstream Mode
Complete Main
Dialogue Level
- 27 dBFS
Frame Rate
29.97 fps
LFE Channel
Disabled
Surround Mode
Not Srnd Encoded
Mdata Scroll
CRC Error
Reporting
On
1.
Turn the Decoder Source control to the AES or SDI channel pair that
contains the Dolby bitstream to be decoded.
2.
You should see the metadata from that Dolby bitstream. Adjust the other
controls if necessary so that you see the data you need.
3.
Follow the instructions on the next page to select which meter channels you
would like to view the decoded channels on.
Now that you have connected a Dolby bitstream source to the Dolby decoder, you