Originalbetriebsanleitung
FLEXI
MIX
2
71
FMII_BAoDB_en_1401 • rs
Maintenance
7.5 High pressure filters
7.5.1 Clean the filter element in the high pressure filter
The cleaning interval for the filter elements in the high pressure filters depends
on the type and cleanliness of the material – however, they must be cleaned at
least 1 x per week and before each material change.
WARNING
If the unit was not depressurised when opening a high-pressure filter, materi-
al may escape under very high pressure and cause serious injuries.
➤
Depressurise the system fully before opening a high pressure filter!
1.
2.
3.
Fig. 87: Remove high pressure filter and filter element
1.
Hold the housing of the high pressure filter with an open end wrench and
then loosen the screw on the mixing unit.
2.
Unscrew the high pressure filter from the mixing unit.
3.
Pull the filter element out from the high pressure filter.
4.
Clean the filter element. For this purpose use only solvents that match the
material to be applied. Replace the filter element if it shows any damage.
5.
Assemble the high pressure filter as described in steps 1- 3, but in reverse
order.
7.5.2 Filter elements for high pressure filters
Insert the filter elements suitable for the spraying material and the spraying
nozzle into the high pressure filters. The mesh size should always be slightly
finer than the bore of the nozzle used.
Mesh
Color
WIWA order number
M 200
red
0467456
M 150
blue
0638200
M 100
yellow
0467448
M 65
black
0646606
Summary of Contents for FLEXIMIX 2 HERKULES Series