Originalbetriebsanleitung
FLEXI
MIX
2
13
FMII_BAoDB_en_1401 • rs
Safety
2.4 Safety features
WARNING
If one of the safety features is missing or not fully functional, the operating
safety of the unit cannot be guaranteed!
➤
If you discover any faults in the safety features or other deficiencies on
the unit, stop operation of the unit immediately.
➤
Only resume operation of the unit after the fault has been completely
eliminated.
Safety features must be checked with the unit depressurized:
➤
before initial commissioning,
➤
always before starting work,
➤
after set-up work,
➤
after all cleaning, servicing and repair work.
Check list:
5
Lead seal on the safety valve still intact?
5
Safety valve free of external damage?
5
Ground cable free of damage?
5
Ground cable connections on unit and conductor in good condition?
5
Function of compressed air shut-off valve correct?
5
Correct functioning of safety levers on spray gun?
The unit is equipped with the following safety features:
➤
Safety valves,
➤
Master switch,
➤
Compressed air shut-off valves
➤
Spray gun lock,
➤
Ground cable.
2.4.1 Safety valves
The
FLEXI
MIX
2
is equipped with
safety valves in its air motors for the
dosing pumps and the flushing pump
(see Fig. 2).
The safety valves ensure that the max.
permissible air inlet pressure is not
exceeded. If the air inlet pressure of the
unit component monitored by the safety
valve exceeds the fixed limit value, the
corresponding safety valve will blow off.
Fig. 2: Safety valve
Summary of Contents for FLEXIMIX 2 HERKULES Series
Page 2: ......