7.4 Maintenance unit
7.4.1 Check the lubricant level in the fog oiler
The fog oiler at the maintenance unit of
FLEXI
MIX
2
PROFESSIONAL and HERKULES supplies the com-
pressed air with pneumatic oil for lubricating the air
motors – the PHOENIX has no fog oiler.
No. Designation
1
Adjusting screw
2
Sight glass
3
Oil filler plug
4
Locking slide
5
Oil tank
The unit must only be commissioned if the oil res-
ervoir of the fog oiler contains enough oil for the air
motors. In case of high humidity, use antifreeze for
lubrication to avoid icing of the air motor.
Fig. 84: Fog oiler
3
2
4
5
1
Check the lubricant level every day as follows:
1.
Press up the locking slide on the oil reservoir and unscrew the oil reservoir
by turning it anti-clockwise.
Take care of the O-ring that seals the oil reservoir. It may be displaced or
even fall out at dismantling.
2.
Check whether the O-ring fits correctly – if necessary, fit it correctly.
3.
Check whether there is enough lubricant – when filled completely, the
lubricant reaches to a point approx. 2 cm below the upper edge of the oil
reservoir.
4.
Top up lubricant, if necessary.
We recommend using pneumatic oil (order number 0632579) or antifreeze
(order number 0631387) from
WIWA
.
5.
Reattach the oil reservoir to the the fog oiler.
7.4.2 Checking and adjusting the fog oiler
1.
Let the unit run slowly under load.
2.
Check in the fog oiler inspection glass whether 1 drop of lubricant is fed
after each 10 to 15 double strokes of the air motors.
3.
If this is not the case, adjust the metering by turning the regulating screw
on the fog oiler with a screwdriver.