Transportation, installation and assembly
4.3.2 Assembling spray hose and spray gun
WARNING
Components that do not comply with the maximum permitted operating pres-
sure of the unit can burst and cause serious injury.
➤
Check the maximum permitted operating pressure of the material hose
and the spray gun before assembly. It must be greater than or equal to
the maximum operating pressure of the unit as specified on the type
plate.
Fit the spray hose to the material outlet of the static mixer:
Fig. 36: Assembly of the spray hose at the standard mixing unit (left)
or at the external mixing unit (right)
Connect the spray hose to the spray gun as described in the operating man-
ual for the spray gun used.
4.3.3 Grounding the unit
Upon delivery the ground cable is already connected to the unit. To ground the
unit, connect the clamp of the ground cable to an electrically conductive object.
4.3.4 Inserting the filter elements into the high pressure filters
Insert the filter elements suitable for the material to be used into the high pres-
sure filters. You can find more information in section 7.5.2 on page 71.