Control module
5.5.5 Filling parameters (Setup fill)
Press the button in the Setup menu shown on the left to open the input window
for entering the filling parameters.
In this input window, enter:
➤
the volume of the spray hose
under “Spray hose volume”.
The formula for calculating the
volume of hoses and a table
of volumes for common hoses
can be found in chapter 10 on
page 79.
“Fill” will be shown on the display
until this volume of material has
left the spray gun after the start of
spraying operation. The aim is to
Fig. 73: Filling parameters part 1
prevent material that is mixed incorrectly or not mixed at all being applied.
➤
The minimum volume that must have left the spray gun after an interrup-
tion in spray operation without flushing before pot life monitoring is reset in
“Volume for potlife reset”. The complete volume of the line system must be
taken into account here (static mixer + hose + safety margin) as otherwise
the full volume of old material will not be expelled.
➤
The mixing tolerance, beyond which the system should switch off automati-
cally during filling in “Mix ratio limit when filling”.
➤
The output of the flushing pump in “Volume flushing pump double stroke".
You will find this value on the flushing pump type plate.
➤
The period that should pass until the Atomizer air malfunction fault mes-
sage will be displayed if the A component does not flow when the air flow
is present in “Delay of atomizer air sensor” (only for
FLEXI
MIX
1
).
Three option buttons follow the input fields (enabled options have a green
background):
➤
“External mixer”: This option should be switched
➤
On
, if you are using an external mixer,
➤
Off
, if you are using a mixer on rack.
The system control must be adjusted to the mixer type used as, in Circula-
tion mode, the metering valves:
➤
must be closed if the mixer is on the rack (Circulation on the "short
route" from the mixing unit back to the material container) and
➤
must be open for an external mixer (Circulation on the "long route" from
the mixer unit through the hose package back to the material container).
➤
“Flush atomizer air”: Switch the atomizer air off when the gun is connect-
ed to the trigger device, as otherwise the cleaning agent is atomized and
escapes into the environment.
➤
“Atomizer air sensor”: The atomizer air sensor monitors the air flow of the
atomizer air in spraying mode (see also “Delay of atomizer air sensor”).