56
Originalbetriebsanleitung
FLEXI
MIX
2
FMII_BAoDB_en_1401 • rs
Control module
5.5.6 Filling level monitoring
Filling level monitoring makes it possible to guarantee a constant supply of ma-
terial and hence to prevent the system being shut down because the material
containers have run dry. The prerequisite for this is that the maximum and mini-
mum filling levels of the material containers are stored in the control system.
Filling level monitoring is a purely computational process. It does not replace
measurement by level sensors.
Press the button in the Setup menu shown on the left to open the input window
for maximum and minimum filling levels.
Fig. 75: Filling level monitoring for valves V1-V3
Fig. 76: Filling level monitoring for valves V4-V6
As the system control monitors the fill levels of up to 10 material containers, but
can only show a maximum of 3 filling levels per window, the display is distribut-
ed across a number of windows. Use the arrow buttons ( and ) to browse
forwards and backwards between the various menu windows. The volume unit
preset in the system control is displayed between these buttons – liters (l.) or
U.S. gallons (gal.).
The Actual line shows the current fill levels of the containers concerned.
Enter for all material containers:
➤
Min
: The minimum filling level at which a message should appear in
the display. In volumetric measurement mode, the unit is automatically
switched off at this level.
➤
Cont
: The size of the container you are using.
Press the Set button after entering the minimum filling level and container size
to save your input for each of the containers.
5.5.7 Valve management
The control system can manage up to
10 valve/pump combinations.
A valve/pump combination comprises
the metering valve and the metering
pump. The data for the valve/pump
combinations used in the unit is re-
corded in Valve management.
Press the button in the Setup menu
shown on the left to open the Valve
management input window.
Fig. 77: Valve management