Control module
Clicking the button after the input field switches the unit between sec and cm³.
If the unit is not equipped with flow rate measuring cells or a flush pump with
shaft encoder or stroke sensor, the flushing volume can not be detected.
In this case, only a time target can be specified for each step of the flushing
program.
Then press the Setup button to open the
action selection.
Use the buttons here to determine what ac-
tion is to be executed in the step concerned.
The Air and Break actions can only be acti-
vated in the low pressure pump if a valve for
air flushing is present.
Once you have defined all the steps in the
flush program, you must specify how many
times this sequence is to be repeated.
Fig. 71: Action selection
5.5.4 Manual valve control
Press the button in the Setup menu shown on the left to open the Manual valve
control window.
The various valves involved in the
function check can be controlled from
here by pressing the relevant button.
The button for the valve currently
open has a green background. Only
one valve can be opened at a time.
An open valve is automatically closed
when another valve is selected. This
prevents material from penetrating
another valve which could trigger
malfunctions.
Fig. 72: Manual valve control
Label
Which valve?
Main valve Shut-off valve for the compressed air inlet
V1 - V10
Metering valves 1-10
Flush A
Flushing valve for A component side
Flush B
Flushing valve for B component side
Flush Air
Air flushing valve
Pressure
Valve for switching between flushing pressure / spraying pressure
Atomizer
Atomizer air valve
Spray gun Spray gun
When checking function, always open the valve first and then fill it by slowly
building up the pressure. This allows potential leaks to be detected quickly and
prevents pressure surges.
The flush valves should always be used at the start and end of the function
check on a material valve to prevent a chemical reaction between any possible
material component residues.