3.11.4 USB interface
The USB interface enables:
➤
downloading the data stored in the control system
(volumes, alarms, etc.) on a USB stick,
➤
updating the software for the control system.
If your
FLEXI
MIX
2
is equipped with a USB interface,
it is located on the control panel left below the control
module. It is marked with the USB symbol.
Fig. 28: USB interface
STOP
RESET
USB
POWER
www.wiwa.de
I
0
I
0
3.11.5 Volumetric measurement valves
The volumetric measurement valves are located on the mixing unit. By default,
the two components are successively filled during control measurement or
volumetric measurement process via one outlet (the spray gun). In contrast,
the two volumetric measurement valves enable separate filling of the A and B
component.
The valves are only opened for control measurement or
volumetric measurement and remain closed otherwise:
➤
turn counterclockwise to open,
➤
turn clockwise to close.
open
close
3.11.6 Spray gun flushing unit
The spray gun flushing unit ensures that
the mixing unit, the spray hose and the
gun are flushed automatically before the
potlife has elapsed. Automatic flushing
prevents the material from hardening in
the machine parts through which mixed
material has flowed.
The potlife will be reset and then start
again after the flushing program has
completed.
The atomizer air is switched off during this
process.
Fig. 29: Spray gun flushing unit
The process continues in cycles until the gun is removed from the retainer.
The period that should elapse until the start of the automatic flushing cycle
can be set in the settings menu. The spray gun trigger unit can be activated or
deactivated here as well (see chapter 5.5.5 on page 54).
Premature removal and incomplete flushing with subsequent replacement does
not reset the potlife (see chapter 6.3 on page 63).
A signal is sent to the control system when the gun has been placed into the
trigger unit and the cover has been closed. Automatic rinsing cannot be carried
out if the gun has not been inserted. The potlife will not be restarted. At the
same time, an error message will appear on the display. Of course it is also
possible to rinse the pistol while it is held by hand.