Transportation, installation and assembly
4 Transportation, installation and assembly
The unit left the factory in flawless condition and was appropriately packed for
transportation.
Check the unit on receipt for any damage in transit and for completeness
.
4.1 Transportation
Please follow these notes when transporting the unit:
➤
Ensure sufficient load bearing capacity of lifting gear and lifting tackle when
loading the unit. You will find the dimensions and weights of the unit on the
machine card.
➤
The unit must only be lifted by the lifting and lashing points provided for this
purpose.
➤
Make sure that the fork tines are long enough when using a forklift truck.
You must guide the fork tines through the two opposite forklift lifting points
on the rack.
➤
When transporting using a fork lift truck, have the forks as far apart as pos-
sible to minimize the overturning moment.
➤
Caution danger of tipping! Ensure even load distribution to secure the sys-
tem against tipping over.
➤
Do not transport any other objects (e.g. material drums) while lifting or
loading the unit.
➤
Never stand under suspended loads or inside the loading area.
This poses a life hazard!
➤
Secure the load on the transport vehicle against slipping and falling off.
If the unit was already operated, please observe the following:
➤
Disconnect the entire unit power supply – even for short transportation
distances.
➤
Empty the unit before transportation – fluid residues may escape during
transportation despite this measure.
➤
Remove all loose parts (e.g. tools) from the unit.
➤
Assemble the parts or fittings dismantled for transport purposes before start
up and in compliance with the intended use of the unit.
4.2 Installation location
By standard the unit is intended for installation outside explosion protected
areas. Only units of explosion protected design may be installed inside EX-
environments.
The ambient temperature has to be between 0 °C and 40 °C.
The unit can be installed inside and outside spray booths. However, outdoor
installation should be preferred in order to avoid contamination.