WPC 2000 User Manual
1128500
Installation
2-33
1.
Check the resolver connector TB106 on the WPC 2000 Main Processor board (see
Figure 2-12, page 2-23 or Figure 2-13, page 2-24) to make sure that the resolver is wired
to the WPC 2000 as instructed on page 2-22.
2.
Locate the 7-conductor shielded resolver cable. Run the cable through 1/2 in. conduit
from the WPC 2000 to the other control. If there is a connector on one end of the cable,
cut it off.
3.
Pull the TB106 resolver connector out of its socket.
4.
Attach the wires to TB106 as shown in Table 2-21, page 2-63 and in Figure 2 at the end of
the manual. You will be wiring in parallel (#104 brown to brown, #105 orange to orange,
etc.), so that when you are finished, you should have two wires of the same color
connected to each terminal on that connector.
5.
Connect the cable from TB106 to the resolver connector in the first “slave” unit.
Remember to wire in parallel.
6.
Locate the master/slave jumper on the Main Processor board of the “slave” unit(s). Move
each of these jumpers to the pins designating “slave.” Refer to the applicable user manual.
7.
Repeat steps 5 and 6 to connect additional “slave” units.
Connecting Other Wintriss Products to WPC 2000
You can connect other Wintriss products to WPC 2000, such as DiPro 1500 and ProCam
1500. Before you wire, complete all WPC 2000 installation, initialization and checkout
procedures. Then run the press in all modes of operation–Inch, Single-stroke, and Continuous
(if applicable). Also make sure that the press has working Top-stop and Emergency-stop
circuits. Since WPC 2000 is connected to the press stop circuits, it is extremely important to
verify that the press operates and stops properly before connecting WPC 2000 to other units.
Do not forget to mark on your electrical prints where you wire in WPC 2000.
When the Stopping Time is critical to your operation, as it is with die protection, be sure to
wire as follows. Whenever you have Emergency-stop circuits, wire them between terminals
#67 and #68 or terminals #68 and #69 on the Main Processor board. For Top-stop circuits,
wire them between terminals #79 and #80 or terminals #80 and #81. Refer to Figure 1 at the
end of the manual for specific wiring schematics.
Use customized status code wiring (see Wiring WPC 2000 User Inputs, page 2-28) when the
auxiliary equipment that you are connecting does not have its own self-explanatory displays,
as are available in DiPro 1500 or AutoSet load analyzers.
Wiring Micro-inch
Micro-inch is a feature that enables you to control the amount of time (and, therefore, the
distance) that the ram moves when the Run/Inch palm buttons are depressed in Inch mode.
Allowing finer adjustments than are possible in Inch, Micro-inch is designed to facilitate setup
on high-speed or short-stroke presses.
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......