1128500
WPC 2000 User Manual
3-6
Initialization, Setup, and Checkout
1.
Press the Reset/Select button repeatedly until the “Stopping Angle” indicator segment
illuminates.
2.
Turn the WPC Settings key switch to “+” (i.e., counterclockwise). The Start Time in
milliseconds that was measured the last time you started the press is shown in the LED
display.
Installing the Overrun Sensor Magnet
This section shows you how to install the magnet that, with the overrun sensor, makes up the
overrun limit switch. You should already have installed the overrun sensor (see page 2-25).
The overrun limit switch enables WPC 2000 to monitor operation of the resolver and to stop
the press whenever the resolver fails to work properly.
The press cannot be run in Continuous or Single-stroke unless the overrun sensor and magnet
are installed and working correctly. Without the overrun limit switch, you can only operate
the press in Inch.
The angle at which you mount the magnet depends on the Top-stop “On” Angle. You must
first determine and set the Top-stop “On” Angle before installing the magnet.
Setting the Top-stop “On” Angle
To determine the angle at which the Top-stop command is given on your press and change the
Top-stop “On” Angle setting on the WPC 2000 display, do the following:
INCORRECT INSTALLATION OF OVERRUN LIMIT SWITCH
Ensure that the overrun sensor magnet is installed at a proper location if you have Two-hand
Control without light curtains, or light curtains with muting. Proper installation of the magnet
ensures that if the Top-stop output relay fails, a hazardous situation will not occur on the
downstroke. The magnet must be mounted as close as possible to the Top-stop “On” Angle (see
Table 3-2, page 3-8).
Failure to comply with these instructions could result in death or serious injury.
For a variable-speed press, you need to determine the latest Top-stop “On” Angle, which is the
angle at which the press top-stops at its slowest speed and with the shortest stopping angle/time.
BEFORE YOU SET THE TOP-STOP “ON” ANGLE, MAKE SURE THAT
• The press ram has been mechanically set to top dead center (TDC) (see NOTICE on page 2-2)
• The resolver has been aligned as close as possible to TDC (i.e., 0° ±2°) (see Mounting the
• The resolver has been zeroed (see page 3-4)
WARNING
!
NOTICE
NOTICE
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......