1128500
WPC 2000 User Manual
3-14
Initialization, Setup, and Checkout
Set the Auto Carry-up Angle at the correct value to protect the operator. To do so, perform
the following steps:
1.
Check to make sure that option switch 7 on switch block S101 on the WPC 2000 Main
Processor board is set to OFF to enable changes to the Auto Carry-up Angle (see
page 3-29).
2.
Power down, then power up the WPC 2000 to enable this settings change.
3.
With the press in Inch mode, press the Reset/Select button repeatedly until the “Auto
Carryup” indicator is lit.
4.
Adjust the Auto Carry-up Angle by turning the WPC Settings key switch to “+”
(counterclockwise) to increase the value or to “–” (clockwise) to decrease the value.
5.
When the value you want is shown in the LED display, save your setting by pressing the
Reset/Select button until the “Angle/SPM” indicator is lit.
6.
Set option switch 7 to ON to disable changes to the Auto Carry-up Angle (see step 1).
7.
Power down WPC 2000, then power the unit back up to enable the new setting.
Running Brake Monitor Tests and Making Settings
WPC 2000’s built-in brake monitor constantly checks the condition of the brake by measuring
the Stopping Time each time the press top-stops. Stopping time is the amount of time in
milliseconds that it takes the crankshaft to stop once the Dual Safety Valve (DSV) has been
de-energized. When the “Stopping Time” indicator is lit, the Stopping Time of the press on
the most recent stroke is shown in the LED display.
The Stop-time Limit is a setting used by the brake monitor to determine when the press needs
to be stopped to alert the operator to the need for brake repair. The Stop-time Limit is
factory-set to 500 milliseconds.
Determining the Stopping Time of Your Press
First, you need to determine the Stopping Time of your press at Top-stop. To do so, perform
the following steps:
1.
Install the heaviest upper die in your press. Adjust the counterbalance for ram weight (if
the press has a counterbalance).
INCORRECT STOP-TIME LIMIT
Determine the Stopping Time and set the Stop-time Limit at a value that reflects the actual
Stopping Time of your press. Use the stop time measured in the 90° stop-time test to calculate the
safety distance.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......