WPC 2000 User Manual
1128500
Initialization, Setup, and Checkout
3-11
•
If the fault code is between F80 and F89 (or H80 through H89), there a problem with the
overrun sensor. Re-check your installation of the magnetic switch (see page 2-25) and
the magnet (see step 2) and your settings for option switches 1 and 2 (see steps 12 and
13 of the Setting the Top-stop “On” Angle procedure, page 3-9), then press the Reset/
Select button and run the press again for a few strokes. If the press stops and the same
error code displays, call Wintriss Tech. Support.
•
If another fault code displays, look up the fault in Chapter 5 and follow the suggested
remedy. After correcting the problem, press the Reset/Select button and run the press
again for a few strokes, checking for faults. If you need assistance, contact Wintriss
Tech. Support.
6.
Permanently install the magnet in the position in which you temporarily mounted it in step
2. Drill and tap a hole, using a No. 36 drill and 6-32 tap. Mount the magnet, plastic side
up, with the 6-32 brass screw provided.
Adjusting the Top-stop Angle
In addition to setting the Top-stop “On” Angle preparatory to mounting the overrun sensor
magnet (see Setting the Top-stop “On” Angle, page 3-6), you can periodically adjust the
Top-stop angle to ensure that your press stops at top dead center. Each time you adjust the
Top-stop angle, you must verify that your overrun sensor is still set properly. To adjust the
Top-stop “On” Angle, do the following:
INJURY FROM MAGNETS THAT DETACH
Mount the magnets with the brass screws provided. Plastic screws or adhesive could fail,
causing the magnets to become dangerous projectiles, especially on high-speed presses.
Failure to comply with these instructions could result in death or serious injury.
Use a brass or other non-ferrous screw to mount the magnet. Steel or ferrous screws can
cause false signals.
INCORRECT OVERRUN SENSOR ANGLE AFTER RESETTING TOP-STOP ANGLE
Re-check the overrun sensor angle setting whenever you change the Top-stop angle, and reset
the overrun sensor setting if necessary.
Failure to comply with these instructions will result in death or serious injury.
WARNING
!
NOTICE
DANGER
!
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......