1128500
WPC 2000 User Manual
2-32
Installation
Auxiliary Output 2
Auxiliary Output 2 is normally open (N/O), or Off. The output closes to ground, or turns on,
whenever there is an interrupted stroke or fault condition or the press is placed in Inch mode.
Auxiliary Output 2 can be connected to the Setup Mode inputs of DiPro 1500 and AutoSet
1500/1504 Plus. The output is used to disable green sensors in DiPro 1500 or repeatability
setpoints in AutoSet 1500/1504 Plus whenever the press is switched to Inch mode or an
interrupted stroke or fault condition occurs. A customer-supplied output relay can be wired
into this circuit. Refer to the applicable manuals for wiring details.
Auxiliary Output 3
Auxiliary Output 3 is normally open (N/O), or Off. The output closes, or turns On, when the
DSV is energized. When Bar Control is in use (see Operating the Press in Bar Mode,
page 4-19), Aux. Output 3 remains open, or Off, when the DSV is energized.
Auxiliary Output 3 can be wired to the input check circuit of DiPro 1500 or ProCam 1500 and
is used to prevent Loss of Rotation faults on these units when Bar Control is activated.
When WPC 2000 is in Bar Control mode, the DSV is energized to enable the crankshaft to be
turned by hand. Under normal conditions, whenever the DSV is energized, Aux. Output 3
turns On, sending a low voltage (i.e., 24 Vdc) input check signal to the DiPro 1500 or ProCam
1500.
DiPro/ProCam 1500 uses the input check signal to initiate monitoring of the programmed start
time limit, the interval within which the crankshaft must begin rotating in order to avoid a
Loss of Rotation fault. In Bar Control mode, Aux. Output 3 disables the input check signal,
preventing the 1500 unit from monitoring the start time limit.
Wire Auxiliary Output 3 to the “A” connection of the input check circuit of DiPro 1500 or
ProCam 1500. Wire one of the +24 Vdc outputs on the WPC 2000 Main Processor board
(pins #37 through #42) to the “B” connection of DiPro 1500 or ProCam 1500. If your DiPro
1500 or ProCam 1500 is equipped with a voltage selector switch for the input check circuit,
set it to the 12-60 volt position. Refer to the DiPro 1500 or ProCam 1500 manual for details.
Connecting Multiple Controls to the Resolver
You can connect the resolver to as many as three additional Wintriss controls (e.g., WPC
2000, DiPro 1500). To do so, perform the following steps:
MAKE WPC 2000 THE “MASTER” WHEN CONNECTING MULTIPLE CONTROLS
When connecting multiple controls to the resolver, make sure that the connection between the
resolver and WPC 2000 is direct, thereby making WPC 2000 the “master” control. Wire the other
Wintriss controls in parallel to the resolver as “slaves.”
NOTICE
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......