1128500
WPC 2000 User Manual
2-28
Installation
Wiring WPC 2000 User Inputs
WPC 2000 user inputs allow you to connect signals from other equipment in order to monitor
auxiliary press functions such as lubrication systems. WPC 2000 provides connections for
two pairs of control-reliable, cross-checked inputs and seven independent inputs that are not
control reliable.
When one of these inputs issues a Stop command by opening a normally closed (N/C) relay, a
fault code for the input(s) appears on the LED display. User inputs 1, 2 and 4 and cross-
checked input pair 8/9 issue an Emergency-stop command. User inputs 3, 5, and 6 generate a
Top-stop command. User input 7 and cross-checked input pair 10/11 generate an Emergency
Stop, simultaneously opening the Lockout relay and displaying the “Loc” message on the
digital LED readout. The stop type, fault code, and wiring connections for each input are
shown in Table 2-3, page 2-29.
USER INPUTS 1 THROUGH 7 NOT SUITABLE FOR SAFETY USE
DO NOT use inputs 1 through 7 as part of any personnel-protection system. These inputs are not
control reliable.
Failure to comply with these instructions will result in death or serious injury.
USER INPUTS ADD DELAY TO STOPPING TIME
DO NOT connect light curtains or other presence-sensing devices to any user inputs. The cross-
checked input pairs (8/9 and 10/11), though control reliable, are suitable only for applications such
as connecting to safety switches used with interlocking barrier guards.
Failure to comply with these instructions will result in death or serious injury.
MAKE SURE TO WIRE CROSS-CHECKED INPUT PAIR CORRECTLY
Input pairs 8/9 and 10/11 are control reliable only if wired correctly in a pair according to the
instructions in this section.
Failure to comply with these instructions will result in death or serious injury.
CHECK PRESS TO MAKE SURE IT STOPS WHEN USER INPUT ACTUATES
• WPC 2000 comes from the factory with the inputs bypassed by jumpers. Make sure to remove
the appropriate jumper from the Main Processor board connector when you wire a user input.
Otherwise, WPC 2000 will not receive the signal from the input. Leave all unused inputs
jumpered/bypassed.
• Perform checkout procedures to ensure that the user inputs are wired correctly and that WPC
2000 responds correctly when the user input faults (see page 3-58).
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
DANGER
!
DANGER
!
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......