Wiring and Settings Tables
A-1
Appendix A. Wiring and Settings Tables
This appendix provides tables identifying wiring connections and switch settings for
components on the AutoSet processor board.
* Ground wire (green or green/yellow) should be connected to ground stud on ceiling of enclosure.
* Shield should be connected to ground stud on enclosure nearest entry of
strain link wiring.
* Shield should be connected to ground stud on enclosure nearest entry of
strain link wiring.
Table A-1. AC Power and Stop Circuit Wiring Connections, TB103
Pin #
Label
Function
Wire Color *
1
HI
AC power
Black
2
NEU
AC power
White (115 VAC), Red (230 VAC)
3
GND
AC power
Not used
4
GND
AC power
Connected to case lug
5
N/O
Stop circuit
N.A.
6
C
Stop circuit
N.A.
Table A-2. Strain Link Wiring Connections, TB105 - TB108: Tension
Pin #
Wire Color *
Function
1
Unused
2
Green
Input +
3
White
Input -
4
Black
Ground
5
Red
Exc +
Table A-3. Strain Link Wiring Connections, TB105 - TB108: Compression
Pin #
Wire Color *
Function
1
Unused
2
White
Input +
3
Green
Input -
4
Black
Ground
5
Red
Exc +