AutoSet User Manual
1137200
Installation
2-15
5.
Wire the connector, as shown in Table 2-4 or Table 2-5. If you mounted the strain links to
read tension, refer to Table 2-4. If you mounted the strain links to read compression, refer
to Table 2-5. Make sure to connect the cable shield to the ground stud on the enclosure
nearest the knockout through which you bring the strain link wiring, as shown in
Figure 2-12, page 2-16.
6.
When you have finished wiring the connector, plug it back into the terminal block from
which you removed it. The connector plugs in only one way. Double-check connections.
7.
Wire the remaining strain link cables, repeating steps 4 through 6.
* Shield should be connected to ground stud on enclosure nearest entry of
strain link wiring.
* Shield should be connected to ground stud on enclosure nearest entry of
strain link wiring.
INCORRECT WIRING CAN DAMAGE STRAIN LINKS
Make sure to connect the black and red wires to the correct terminals as shown in
Table 2-4 or Table 2-5. If you reverse the wiring, the strain link can be damaged.
Failure to comply with these instructions could result in property damage.
Table 2-4. Strain Link Wiring Connections, TB105 - TB108: Tension
Pin #
Wire Color *
Function
1
Unused
2
Green
Input +
3
White
Input -
4
Black
Ground
5
Red
Exc +
Table 2-5. Strain Link Wiring Connections, TB105 - TB108: Compression
Pin #
Wire Color *
Function
1
Unused
2
White
Input +
3
Green
Input -
4
Black
Ground
5
Red
Exc +
CAUTION