2.
On standard AutoSets, press the RESET button and hold for at least two seconds or until
the LED displays flash
or
On AutoSet Plus load analyzers, turn the DISPLAY switch to the RESET position and
hold for at least two seconds or until the LED displays flash.
The next time you run the press, AutoSet clears the old setpoints and displays high
tonnage setpoints that are 120% of press capacity and repeatability setpoints that are 120%
of press capacity.
Turning Off and Restoring Power
When power to the AutoSet is turned off, Load and Setpoints LED readings are lost.
However, since calibration and full-scale tonnage settings are intact, AutoSet will display
correct Load and Setpoints values when power is restored and setpoints recalculated. When
power is first restored, the Load displays will read zero and the Setpoints displays show values
that are 120% of full-scale tonnage. When you restart the press, AutoSet will recalculate
setpoints after the number of strokes set for the sample period, displaying those setpoints in
the Setpoints LEDs and the tonnage for the current stroke in the Load LEDs.