1137200
AutoSet User Manual
A-2
Wiring and Settings Tables
Table A-4. TB101A and TB101B Wiring Connections
TB 101
A or B
Pin No.
Auto Set 1500
(TB101B)
Function
AutoSet 1500+
(TB101B)
Function
AutoSet 1504
(TB101A)
Function
AutoSet 1504+
(TB101A)
Function
1
Remote Reset
Remote Reset
Remote Reset
Remote Reset
2
Zero Cam
Zero Cam
Zero Cam
Zero Cam
3
Aux Out
Aux Out
Aux Out
Aux Out
4
+12 VDC
+12 VDC
+12 VDC
+12 VDC
5
Ground
Ground
Unused
Setup
6
Ch 1 Out
Ch 1 Out
Ch 1 Out
Ch 1 Out
7
Ch 2 Out
Ch 2 Out
Ch 2 Out
Ch 2 Out
8
Unused
Setup
Ch 3 Out
Ch 3 Out
9
Ch 4 Out
Ch 4 Out
10
Ground
Ground
Table A-5. Mode Switch (S101) Settings
Switch No.
Function and Settings
1
Sample Period Length. Specifies the number of strokes in the sample
period. Settings are:
OFF 15 strokes
ON
1 stroke
2
Zero Cam Enable/Disable. Enables and disables the zero cam
function. Settings are:
OFF Disable Zero Cam
ON Enable Zero Cam
3
Decimal Point On/Off. Indicates whether a one-position decimal point
(e.g., 55.5) is used in tonnage displays. Settings are:
OFF Decimal point on
ON Decimal point off
4
Unused
5
Setup Mode Enable/Disable. Enables or disables the Setup Mode
circuit if one has been wired (see page 2-22). Settings are:
OFF Setup Mode enabled
ON Setup Mode disabled
6
AutoSet Number. Identifies each AutoSet module when two AutoSets
are connected to one SmartPAC control. You must set this switch on
both boards. Settings are:
OFF AutoSet 1
ON AutoSet 2
7
4-Channel-to-2-Channel Conversion. When enabled, causes a
4-channel AutoSet to operate like a 2-channel unit. Settings are:
OFF Conversion disabled (Default).
ON Conversion enabled. 4-channel AutoSet operates like a
2-channel unit.
8
Unused
Summary of Contents for autoset 1500