AutoSet User Manual
1137200
Calibration
3-15
* Displayed tonnage can be up to 120% of press capacity
3.
Power down the AutoSet, then power the unit back up to reset the load analyzer and
activate the settings made on the tonnage indicator dials and Mode switch #3.
Adjusting AutoSet to Read the Correct Tonnage
To adjust the tonnage displayed on your AutoSet load analyzer so it agrees with the value(s)
shown on the calibration unit, perform the following steps:
1.
With the cover of the AutoSet enclosure open, move the lever on switch S102 at the upper
right of the AutoSet processor board to the “OPERATE” position (see Figure 2-4 or
Figure 2-5).
2.
Familiarize yourself with the gain adjustment potentiometers and high/low gain jumpers
to the left of the strain link inputs at the bottom of the AutoSet processor board (see
Figure 2-4 or Figure 2-5). Table 3-5, page 3-16 shows the processor board labels that
identify potentiometers and jumpers for each AutoSet model.
Table 3-4. AutoSet 1504 and 1504 Plus Tonnage Display Formats
Load Cell
Tonnage Range
Mode Switch
#3 Setting
Decimal Point
ON/OFF
Channel Load LED Display
Format *
†
400 tons or less
OFF
ON
Up to 100 tons: tenths of a ton (e.g.,
6.0, 45.5., 99.9)
From 100 to 120 tons: whole tons
(e.g., 100, 109, 120)
ON
OFF
Whole tons (e.g., 6, 46, 100)
401 to 3000 tons
ON
OFF
Whole tons (e.g., 125, 400, 750)
More than 3010 tons
OFF
ON
Tenths of a ton (e.g., 5.5 = 55 tons,
25.0 = 250 tons, 99.9 = 999 tons)
ON
OFF
Whole tons (e.g., 6 = 60 tons, 25 =
250 tons, 100 = 1000 tons)
Switch S102 should have been set to “OPERATE” at the end of the strain link zeroing
procedure. See
NOTICE