1137200
AutoSet User Manual
1-6
Introduction
AutoSet Faults
AutoSet stops the press whenever the measured tonnage exceeds the high setpoint or the
stroke-to-stroke tonnage variation exceeds the repeatability setpoint for one or more of the
strain links.
To clear the error condition, you press the RESET button (AutoSet 1500) or turn the
DISPLAY switch to the RESET position (AutoSet 1504). The button or switch should be
held for less than two seconds; otherwise, AutoSet will recalculate setpoints.
AutoSet fault conditions are covered in Chapter 5.
AutoSet Specifications
AutoSet specifications are shown in Table 1-1.
Table 1-1. AutoSet Specifications
Equipment
System enclosure 10.25” (260.4 mm) x 12” (304.8 mm) x 4”
(101.6 mm), NEMA 12, shock-mounted
Power
115 or 230 Vac ±15%, 50-60 Hz, 30 W
Operating temperature
32
o
to 122
o
F (0
o
to 50
o
C)
Relay contact rating
4 amps @ 120 or 240 Vac
Normally open, held closed
Speed
to 2000 SPM
Display
AutoSet 1500/1500+
Two 3-digit .43” (10.9 mm) high for tonnages
Two 3-digit .30” (7.6 mm) high for setpoints
AutoSet 1504/1504+
Four 3-digit .43” (10.9 mm) high for tonnages
Four 3-digit .30” (7.6 mm) high for setpoints
One 4-digit .43” (10.9 mm) high for total tonnage
Strain links
Size
Cable
Two (1500/1500+) or four (1504/1504+) provided
3.75” (95.3 mm) x 1.19” (30.2 mm) x 0.75” (19.1 mm)
30 ft. (9.1 m) standard, other lengths optional
Drill jig
One provided