5
1.
Important information for system operators
1.2 Safety precautions
The boiler and related accessories are state of the art and meet all applicable safety regulations and operate
using 230 V AC electrical current. Improper installation or repair can pose the danger of life-threatening electrical
shock. Installation may be performed only by appropriately qualified technicians.
Caution symbols
Please take careful note of the following symbols in this Operating Manual.
1.3 Sources of danger
1.3.1 Power failure
(or if the blower is not running)
Attention!
Do not open the combustion chamber door, there is an increased risk of deflagration when opening
the combustion chamber door. A self-test is performed following a power failure during combustion
and then operation is continued automatically.
1.3.2 Burner pot
Attention!
Never fill the burner pot with pellets by hand. Excessive combustion material in the burner pot me-
ans that the pellets will not be ignited optimally. Too much low temperature carburisation gas will
be generated and this can lead to deflagration.
Please note: Risk of crushing from rotating auger.
If you have to touch these parts, always deenergise the boiler.
Warning of hot surface: risk of burns!
Before touching these surfaces, you must switch off the boiler and let it cool.
Attention!
Ignoring the warnings identified can lead to
personal injury
.
Information!
Ignoring the warnings identified can lead to
malfunction of, or damage to the boiler or heating
system
.
Note!
The blocks of text highlighted provide
information and tips
for operation.