21
2.
Operation
2.8.2 Pellet consumption
The amount of pellets used since filling and the total amount of used pellets is
shown in tonnes.
Note!
The “Pellet consumption” is a calculated value and can differ from
the actual value by ±15 %.
2.8.3 Boiler values
Flue gas temperature
This function displays the current flue gas temperature..
Information!
The flue gas temperature is measured directly on the flue outlet. It
may therefore deviate from a standard measurement.
Boiler temperature setpoint
The display indicates the boiler temperature setpoint as calculated by the con-
trol system. This setpoint is used to control the burner.
Boiler output
The current boiler output is displayed in %. The boiler output (modulation mode)
can be set from 30 % to 100 %.
Operating hours
The total number of burner operating hours is displayed.
Burner starts
The number of burner starts of the BioWIN 2 is displayed.
2.8.4 Software version
Display module
The current software version of the display module (InfoWINplus) is displayed.
Firing automate
The current software version of the firing automate (main PCB) is displayed.
BW II
The boiler model is displayed.
Boiler no. (Heat generator nummer)
Shows the set heat generator number.
Single boiler = 0
Cascade = 1 – 4
Pellet consumption
since bulk fill
2,78 t
total
36,57 t
Back
Fig. 39
Fig. 40
Boiler values
Flue gas temperature
148 °C
Boiler temp. setpoint
63 °C
Boiler output
70 %
Operating hours
1234 h
Burner starts
1350
Back
Fig. 41
Software version
Display module
3.00
Firing automate
1.00
BW II
100E
Boiler no.
0
Back