2.
Operation
2.6 Operating modes
2.6.1 OFF mode
The boiler is switched off when in OFF mode. The dis-
play and all buttons, with the exception of the
ON/OFF
button, do not function. The LED on the InfoWINplus
does not light up – Fig. 12.
2.6.2 ON mode, lighting ON, self-
test, lighting OFF
Press the
ON/OFF
button, lighting and display are swit-
ched on and the self-test starts automatically – Fig. 13.
Self-test:
Sensors, switches and motors are checked during the
self-test.
After a successful self-test, the display shows an opera-
ting phase and the boiler water temperature (standard
display). The LED control lamp lights up green and the
desired functions can be selected using the buttons –
Fig. 14.
If the self-test was unsuccessful, an information mes-
sage (e.g. information, fault, alarm) is displayed (see
sections 4).
Lighting ON/OFF
The display lighting switches off automatically after 10
minutes. (Fig. 15). Pressing one of the six buttons swit-
ches the lighting on again for 10 minutes.
InfoWINplus identifies and stores the various opera-
ting modes and states. Once the system is switched on,
other operating modes may also be displayed instead of
the standard display, such as manual operation, solid
fuel or accumulator tank operation; malfunctions are
also displayed. These operating modes and states are
described later in these instructions.
Fig. 12 OFF mode
Fig. 13 Self-test
Fig. 14 Standard display
Boiler temperature
(Operating phases)
Info
Menu
42
°C
Fig. 15 Display lighting ON
Boiler temperature
(Operating phases)
Lighting ON
42
°C
Self-test
active
(Animated symbol)