11
2.
Operation
2.2.2 BioWIN 2 Premium
Version as BioWIN Klassik, but in addition with fully automatic pellet feed
The pellet feed uses a maintenance-free suction turbine to fill the BioWIN 2 reserve supply container fully auto-
matically with pellets from a pellet storage room or storage container. The pellet feed is switched on by the lower
fill level switch (proximity switch) in the reserve supply container or at the end of the enable time or the beginning
of the start time, and runs for as long as the reserve supply container is full. Filling is not started if the boiler is
in heating operation or the feed has been blocked by the control unit (not during the enable time e.g. at night). If
the boiler is operating when filling is necessary, the boiler switches to burnout mode.
When there are several suction probes, switching to the suction probes is executed automatically. The system
changes to the next suction probe after the reserve supply container has been filled a certain number of times.
This means the storage room is evenly emptied to a large extent.
1 ........... Inspection cover Reserve supply container under cover
2 ........... Water tank for burn-back safeguard
(behind reserve supply container)
3 ........... Pellet reserve supply container
4 ........... Fully automatic pellet feed
5 ........... Device fuse T 6.3 A
6 ........... Safety thermostat for auger tube
7 ........... Safety thermostat for boiler temperature
8 ........... InfoWINplus operating unit
9 ........... Control module (only in MESplus control)
10 ......... Down chute
11 ......... Burner pot
12 ......... Coasting surface cover for the ash-chamber coasting surface
13 ......... Ash pan
14 ......... Filling and evacuation cock
15 ......... Cleaning brush
16 ......... Spatula
17 ......... Allen key
18 ......... Scratcher
19 ......... Pellet pile
1
(accessories)
1
2
3
4
14
5 6 7
8
9
10
11
12
13
Fig. 9
BioWIN 2 Premium without combustion chamber door and with open cladding door
15 16 17 18 19
1
pellet pile for bridging purposes or when manually filling the integral fuel hopper, if feed is not complete
.