W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 51 -
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
CK#
CK
Command
*3
READ
Address
*4
NOP
NOP
NOP
NOP
READ
NOP
Bank
Col n
DQS, DQS#
DQ
*2
RL = 6
Dout
n
Dout
n+1
RL = 6
t
RPRE
Dout
n+2
Dout
n+3
t
RPST
NOP
NOP
NOP
T11
T12
T13
T14
NOP
Bank
Col b
NOP
NOP
NOP
NOP
t
RPRE
Dout
b
Dout
b+1
Dout
b+2
Dout
b+3
t
RPST
t
CCD
TRANSITIONING DATA
DON'T CARE
NOTES:
1. BC4, RL = 6 (CL = 6, AL = 0)
2. Dout n (or b) = data-out from column n (or column b).
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BC4 setting activated by either MR0 A[1:0] = 10 or MR0 A[1:0] = 01 and A12 = 0 during READ commands at T0 and T4.
Figure 31
– READ (BC4) to READ (BC4)
T0
T1
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK#
CK
Command
*3
READ
Address
*4
NOP
NOP
NOP
NOP
NOP
Bank
Col n
DQS, DQS#
DQ
*2
RL = 6
Dout
n
Dout
n+1
WL = 5
t
RPRE
Dout
n+2
Dout
n+3
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
t
WPST
NOP
NOP
WRITE
T12
T13
T14
T15
Bank
Col b
NOP
NOP
NOP
NOP
Din
b
Din
b+1
Din
b+2
Din
b+3
Din
b+4
Din
b+5
Din
b+6
Din
b+7
T16
NOP
NOP
NOP
t
RPST
t
WPRE
4 clocks
t
WR
t
WTR
TRANSITIONING DATA
DON'T CARE
NOTES:
1. BL8, RL = 6 (CL = 6, AL = 0), WL = 5 (CWL = 5, AL = 0)
2. Dout n = data-out from column, Din b = data-in from column b.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BL8 setting activated by either MR0 A[1:0] = 00 or MR0 A[1:0] = 01 and A12 = 1 during READ command at T0 and WRITE command at T7.
READ to WRITE Command Delay = RL + t
CCD
+ 2t
CK
- WL
TIME BREAK
Figure 32
– READ (BL8) to WRITE (BL8)