W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 64 -
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
Din
n
Din
n+2
WL = 5
t
WPRE
Din
n+1
t
WPST
t
WTR
T12
T11
T13
T14
Din
n+3
RL = 6
NOTES:
1. RL = 6 (CL = 6, AL = 0), WL = 5 (CWL = 5, AL = 0)
2. Din n = data-in from column n; Dout b = data-out from column b.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BC4 setting activated by MR0 A[1:0] = 01 and A12 = 0 during WRITE command at T0.
READ command at T13 can be either BC4 or BL8 depending on MR0 A[1:0] and A12 status at T13.
CK#
CK
Command
*3
Address
*4
DQS, DQS#
DQ
*2
WRITE
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
READ
NOP
NOP
NOP
NOP
TRANSITIONING DATA
DON'T CARE
Bank
Col b
Bank
Col n
4 clocks
Figure 51
– WRITE (BC4) to READ (BC4/BL8) OTF
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
Din
n
Din
n+2
WL = 5
t
WPRE
Din
n+1
t
WPST
t
WTR
T12
T11
T13
T14
Din
n+3
RL = 6
NOTES:
1. RL = 6 (CL = 6, AL = 0), WL = 5 (CWL =5, AL = 0)
2. Din n = data-in from column n; Dout b = data-out from column b.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BC4 setting activated by MR0 A[1:0] = 10.
CK#
CK
Command
*3
Address
*4
DQS, DQS#
DQ
*2
WRITE
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
READ
NOP
TRANSITIONING DATA
DON'T CARE
Bank
Col b
Bank
Col n
Figure 52
– WRITE (BC4) to READ (BC4)