W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 63 -
Din
n
Din
n+2
Din
n+3
WL = 5
t
WPRE
Din
n+1
t
WPST
WL = 5
Din
b
Din
b+1
Din
b+3
Din
b+2
t
WPRE
t
WPST
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
4 clocks
T12
T11
T13
T14
t
WR
t
WTR
t
CCD
NOTES:
1. BC4, WL = 5 (CWL = 5, AL = 0)
2. Din n (or b) = data-in from column n (or column b).
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BC4 setting activated by MR0 A[1:0] = 01 and A12 = 0 during WRITE command at T0 and T4.
5. The write recovery time (tWR) and write timing parameter (tWTR) are referenced from the first rising clock edge at T13 (4 clocks from T9).
CK#
CK
Command
*3
Address
*4
DQS, DQS#
DQ
*2
WRITE
NOP
NOP
NOP
NOP
WRITE
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
TRANSITIONING DATA
DON'T CARE
Bank
Col b
Bank
Col n
Figure 49
– WRITE (BC4) to WRITE (BC4) OTF
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
Din
n
Din
n+2
Din
n+3
WL = 5
t
WPRE
Din
n+1
t
WPST
t
WTR
T12
T11
T13
T14
Din
n+5
Din
n+6
Din
n+4
Din
n+7
RL = 6
NOTES:
1. RL = 6 (CL = 6, AL = 0), WL = 5 (CWL = 5, AL = 0)
2. Din n = data-in from column n; Dout b = data-out from column b.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BL8 setting activated by either MR0 A[1:0] = 00 or MR0 A[1:0] = 01 and A12 = 1 during WRITE command at T0.
READ command at T13 can be either BC4 or BL8 depending on MR0 A[1:0] and A12 status at T13.
CK#
CK
Command
*3
Address
*4
DQS, DQS#
DQ
*2
WRITE
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
NOP
READ
NOP
NOP
NOP
NOP
TRANSITIONING DATA
DON'T CARE
Bank
Col b
Bank
Col n
Figure 50
– WRITE (BL8) to READ (BC4/BL8) OTF