8.13.2.6 Burst Read Operation followed by a Precharge
The minimum external Read command to Precharge command spacing to the same bank is equal to AL + t
RTP
with t
RTP
being the Internal Read
Command to Precharge Command Delay. Note that the minimum ACT to PRE timing, t
RAS.MIN
must be satisfied as well. The minimum value for the
Internal Read Command to Precharge Command Delay is given by t
RTP.MIN
= max(4 × nCK, 7.5 nS). A new bank active command may be issued to the
same bank if the following two conditions are satisfied simultaneously:
1. The minimum RAS precharge time (t
RP.MIN
) has been satisfied from the clock at which the precharge begins.
2. The minimum RAS cycle time (t
RC.MIN
) from the previous bank activation has been satisfied.
Examples of Read commands followed by Precharge are show in Figure 38 and Figure 39.
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
CK#
CK
Command
NOP
Address
READ
NOP
ACT
PRE
NOP
NOP
Bank a,
Col n
DQS, DQS#
DQ
NOP
NOP
NOP
T11
T12
T13
T14
NOP
Bank a,
(or all)
NOP
NOP
NOP
NOP
Dout
n
Dout
n+1
Dout
n+2
Dout
n+3
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
t
RTP
Dout
n
Dout
n+1
Dout
n+2
Dout
n+3
DQS, DQS#
DQ
BL4 Operation:
BL8 Operation:
t
RP
RL = AL + CL = 9
TRANSITIONING DATA
DON'T CARE
NOTES:
1. RL = 9 (CL = 9, AL = 0)
2. Dout n = data-out from column n.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. The example assumes t
RAS.MIN
is satisfied at Precharge command time (T5) and that t
RC.MIN
is satisfied at the next Active command time (T14).
Bank a,
Row b
T15
NOP
Figure 38
– READ to PRECHARGE (RL = 9, AL = 0, CL = 9, t
RTP
= 4, t
RP
= 9)