W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 129 -
Table 44
– I
DD4R
and I
DDQ4R
Measurement-Loop Pattern
1
C
K
,
C
K
#
CKE
S
ub
-Lo
op
C
y
c
le
N
um
ber
C
om
m
a
nd
C
S
#
R
A
S
#
C
A
S
#
W
E
#
OD
T
B
A
[2
:0
]
A
[1
3
:1
1
]
A
[1
0
]
A
[9
:7
]
A[
6
:3
]
A
[2
:0
]
Data
2
to
g
g
lin
g
S
ta
tic
H
igh
0
0
RD
0
1
0
1
0
0
0
0
0
0
0
00000000
1
D
1
0
0
0
0
0
0
0
0
0
0
-
2, 3
D#, D#
1
1
1
1
0
0
0
0
0
0
0
-
4
RD
0
1
0
1
0
0
0
0
0
F
0
00110011
5
D
1
0
0
0
0
0
0
0
0
F
0
-
6, 7
D#, D#
1
1
1
1
0
0
0
0
0
F
0
-
1
8-15
Repeat Sub-Loop 0, but
BA[2:0] = 1
2
16-23
Repeat Sub-Loop 0, but
BA[2:0] = 2
3
24-31
Repeat Sub-Loop 0, but
BA[2:0] = 3
4
32-39
Repeat Sub-Loop 0, but
BA[2:0] = 4
5
40-47
Repeat Sub-Loop 0, but
BA[2:0] = 5
6
48-55
Repeat Sub-Loop 0, but
BA[2:0] = 6
7
56-63
Repeat Sub-Loop 0, but
BA[2:0] = 7
Notes:
1. DM must be driven LOW all the time. DQS, DQS# are used according to RD Commands, otherwise MID-LEVEL.
2. Burst Sequence driven on each DQ signal by Read Command. Outside burst operation, DQ signals are MID-LEVEL.
Table 45
– I
DD4W
Measurement-Loop Pattern
1
C
K
,
C
K
#
CKE
S
ub
-Lo
op
C
y
c
le
N
um
ber
C
om
m
a
nd
C
S
#
R
A
S
#
C
A
S
#
W
E
#
OD
T
B
A
[2
:0
]
A
[1
3
:1
1
]
A
[1
0
]
A
[9
:7
]
A[
6
:3
]
A
[2
:0
]
Data
2
to
g
g
lin
g
S
ta
tic
H
igh
0
0
WR
0
1
0
0
1
0
0
0
0
0
0
00000000
1
D
1
0
0
0
1
0
0
0
0
0
0
-
2, 3
D#, D#
1
1
1
1
1
0
0
0
0
0
0
-
4
WR
0
1
0
0
1
0
0
0
0
F
0
00110011
5
D
1
0
0
0
1
0
0
0
0
F
0
-
6, 7
D#, D#
1
1
1
1
1
0
0
0
0
F
0
-
1
8-15
Repeat Sub-Loop 0, but
BA[2:0] = 1
2
16-23
Repeat Sub-Loop 0, but
BA[2:0] = 2
3
24-31
Repeat Sub-Loop 0, but
BA[2:0] = 3
4
32-39
Repeat Sub-Loop 0, but
BA[2:0] = 4
5
40-47
Repeat Sub-Loop 0, but
BA[2:0] = 5
6
48-55
Repeat Sub-Loop 0, but
BA[2:0] = 6
7
56-63
Repeat Sub-Loop 0, but
BA[2:0] = 7
Notes:
1. DM must be driven LOW all the time. DQS, DQS# are used according to WR Commands, otherwise MID-LEVEL.
2. Burst Sequence driven on each DQ signal by Write Command. Outside burst operation, DQ signals are MID-LEVEL.