9. Parameters Configuration
9.1 General
The parameters configuration of the ESPE can be carried out via:
)
The following applies invariably:
• Parameter configuration is only possible after the password has been entered.
• The parameter configuration on the sensor has priority over parameter configuration via IO-Link.
• The OSSDs are off during parameter configuration.
• If no key input or input via the IO-Link interface is registered for 300 s, the sensor switches to a safe state.
• The last selected setting resets contradictory settings.
NOTE!
• Changes to the configuration may only be made by authorized personnel.
• The required password must be managed with suitable security.
9.2 Preparation of the Parametrization
Before carrying out a new parameter configuration for an ESPE, the following preparations must be made:
• All new settings (e.g. contactor monitoring, range, beam coding, …) must be planned and documented
beforehand.
• A check must be carried out to ensure correct mounting and electrical connection of the ESPE.
9.3 Parametrization of the Emitter
The parameter configuration directly on the sensor takes place via the push buttons on the control panel.
Emitter
Menu down
Apply
NOTE!
If the parameter configuration is interrupted (e.g. due to an interruption in the power supply),
this causes the newly selected settings to be lost. In this case, the most recently saved