Safety Light Curtain
41
a [mm]
Height of the
danger zone
C
RO
[mm]
Additional horizontal clearance from the danger zone
2600
0
0
0
0
0
0
0
0
0
0
0
0
2500
400
400
350
300
300
300
300
300
250
150
100
0
2400
550
550
550
500
450
450
400
400
300
250
100
0
2200
800
750
750
700
650
650
600
550
400
250
0
0
2000
950
950
850
850
800
750
700
550
400
0
0
0
1800
1100 1100
950
950
850
800
750
550
0
0
0
0
1600
1150 1150 1100 1000
900
850
750
450
0
0
0
0
1400
1200 1200 1100 1000
900
850
650
0
0
0
0
0
1200
1200 1200 1100 1000
850
800
0
0
0
0
0
0
1000
1200 1150 1050
950
750
700
0
0
0
0
0
0
800
1150 1050
950
800
500
450
0
0
0
0
0
0
600
1050
950
750
550
0
0
0
0
0
0
0
0
400
900
700
0
0
0
0
0
0
0
0
0
0
200
600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
b [mm]
Height of the top edge of the safety field
900
1000 1100 1200 1300 1400 1600 1800 2000 2200 2400 2600
Table 8.2.2: Extract from table 1, EN ISO 13855